The Injurious Effects of Elevated or Nonelevated Respiratory Rate during Mechanical Ventilation

Am J Respir Crit Care Med. 2019 Jan 15;199(2):149-157. doi: 10.1164/rccm.201804-0726CI.

Abstract

Respiratory rate is one of the key variables that is set and monitored during mechanical ventilation. As part of increasing efforts to optimize mechanical ventilation, it is prudent to expand understanding of the potential harmful effects of not only volume and pressures but also respiratory rate. The mechanisms by which respiratory rate may become injurious during mechanical ventilation can be distinguished in two broad categories. In the first, well-recognized category, concerning both controlled and assisted ventilation, the respiratory rate per se may promote ventilator-induced lung injury, dynamic hyperinflation, ineffective efforts, and respiratory alkalosis. It may also be misinterpreted as distress delaying the weaning process. In the second category, which concerns only assisted ventilation, the respiratory rate may induce injury in a less apparent way by remaining relatively quiescent while being challenged by chemical feedback. By responding minimally to chemical feedback, respiratory rate leaves the control of V. e almost exclusively to inspiratory effort. In such cases, when assist is high, weak inspiratory efforts promote ineffective triggering, periodic breathing, and diaphragmatic atrophy. Conversely, when assist is low, diaphragmatic efforts are intense and increase the risk for respiratory distress, asynchronies, ventilator-induced lung injury, diaphragmatic injury, and cardiovascular complications. This review thoroughly presents the multiple mechanisms by which respiratory rate may induce injury during mechanical ventilation, drawing the attention of critical care physicians to the potential injurious effects of respiratory rate insensitivity to chemical feedback during assisted ventilation.

Keywords: control of breathing; diaphragmatic dysfunction; patient–ventilator interaction; respiratory rate; ventilator-induced lung injury.

Publication types

  • Review

MeSH terms

  • Humans
  • Lung / physiopathology*
  • Respiration, Artificial / methods*
  • Respiratory Rate / physiology*
  • Ventilator Weaning
  • Ventilator-Induced Lung Injury / physiopathology