Format

Send to

Choose Destination
World Neurosurg. 2018 Dec;120:e326-e332. doi: 10.1016/j.wneu.2018.08.069. Epub 2018 Aug 23.

Visual Field Outcome Reporting in Neurosurgery: Lessons Learned from a Prospective, Multicenter Study of Transsphenoidal Pituitary Surgery.

Author information

1
Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA.
2
Horizon Eye Specialists and Lasik Center, Phoenix, Arizona, USA.
3
Biltmore Eye Physicians, Phoenix, Arizona, USA.
4
Department of Neurological Surgery, University of Washington School of Medicine, Seattle, Washington, USA.
5
Pacific Brain Tumor Center and Pituitary Disorders Program, John Wayne Cancer Institute at Providence St. John's Health Center, Santa Monica, California, USA.
6
Department of Neurological Surgery, University of Pittsburgh Medical Center, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania, USA.
7
Department of Neurological Surgery, The Ohio State University, Columbus, Ohio, USA.
8
Department of Neurological Surgery, Washington University School of Medicine, St. Louis, Missouri, USA.
9
Department of Neurological Surgery, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.
10
Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA. Electronic address: neuropub.little@barrowneuro.org.

Abstract

OBJECTIVE:

Visual field (VF) outcomes are commonly reported in neurosurgical case series; however, substantial variability can exist in VF testing and outcome reporting. We aimed to evaluate the challenges of VF testing and to develop detailed recommendations for VF outcome reporting by analyzing results from an ongoing, multicenter study of transsphenoidal pituitary surgery.

METHODS:

VF testing results were collected during a prospective, multicenter clinical trial evaluating patient outcomes after transsphenoidal surgery for nonfunctioning pituitary adenomas (TRANSSPHER). Two independent ophthalmologists reviewed reliability and outcomes of all VF studies. Preoperative and postoperative VF studies were evaluated individually and as preoperative/postoperative pairs.

RESULTS:

Suboptimal perimetry field settings were reported in 37% of VF studies. Automated reliability criteria flagged 25%-29% of VF studies as unreliable, whereas evaluation by 2 independent ophthalmologists flagged 16%-28%. Agreement between automated criteria and raters for VF reliability was inconsistent (κ coefficients = 0.55-0.83), whereas agreement between the 2 raters was substantial to almost perfect (κ coefficients = 0.78-0.83). Most patients demonstrated improvement after surgery (rater 1, 67%; rater 2, 60%), with substantial rater agreement on outcomes for paired examinations (κ coefficient = 0.62).

CONCLUSIONS:

VF outcome studies demonstrated significant variability of test parameters and patient performance. Perimetry field settings varied among patients and for some patients varied preoperatively versus postoperatively. Reliance on automated criteria alone could not substitute for independent ophthalmologist review of test reliability. Standardized guidelines for VF data collection and reporting could increase reliability of results and allow better comparisons of outcomes in future studies.

KEYWORDS:

Guidelines; Outcome reporting; Pituitary; Transsphenoidal; Visual field