Format

Send to

Choose Destination
PLoS One. 2018 Jul 31;13(7):e0201632. doi: 10.1371/journal.pone.0201632. eCollection 2018.

Evaluation of the SpO2/FiO2 ratio as a predictor of intensive care unit transfers in respiratory ward patients for whom the rapid response system has been activated.

Kwack WG1,2, Lee DS3, Min H3, Choi YY3, Yun M3, Kim Y1,2, Lee SH1,2, Song I4, Park JS1,2, Cho YJ1,2, Jo YH5, Yoon HI1,2, Lee JH1,2, Lee CT1,2, Lee YJ1,2.

Author information

1
Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.
2
Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea.
3
Interdepartment of Critical Care Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.
4
Department of Anesthesiology, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.
5
Department of Emergency Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.

Abstract

Efforts to detect patient deterioration early have led to the development of early warning score (EWS) models. However, these models are disease-nonspecific and have shown variable accuracy in predicting unexpected critical events. Here, we propose a simpler and more accurate method for predicting risk in respiratory ward patients. This retrospective study analyzed adult patients who were admitted to the respiratory ward and detected using the rapid response system (RRS). Study outcomes included transfer to the intensive care unit (ICU) within 24 hours after RRS activation and in-hospital mortality. Prediction power of existing EWS models including Modified EWS (MEWS), National EWS (NEWS), and VitalPAC EWS (ViEWS) and SpO2/FiO2 (SF) ratio were compared to each other using the area under the receiver operating characteristic curve (AUROC). Overall, 456 patients were included; median age was 75 years (interquartile range: 65-80) and 344 (75.4%) were male. Seventy-three (16.0%) and 79 (17.3%) patients were transferred to the ICU and died. The SF ratio displayed better or comparable predictive accuracy for unexpected ICU transfer (AUROC: 0.744) compared to MEWS (0.744 vs. 0.653, P = 0.03), NEWS (0.744 vs. 0.667, P = 0.04), and ViEWS (0.744 vs. 0.675, P = 0.06). For in-hospital mortality, although there was no statistical difference, the AUROC of the SF ratio (0.660) was higher than that of each of the preexisting EWS models. In comparison with the preexisting EWS models, the SF ratio showed better or comparable predictive accuracy for unexpected ICU transfers in the respiratory wards.