Transfusion. 2018 Sep;58(9):2202-2207. doi: 10.1111/trf.14652. Epub 2018 May 6.

Inactivation of Ebola virus and Middle East respiratory syndrome coronavirus in platelet concentrates and plasma by ultraviolet C light and methylene blue plus visible light, respectively.

Author information

1
Institute for Virology, Philipps University Marburg, Marburg, Germany.
2
German Red Cross Blood Service NSTOB, Springe, Germany.
3
Macopharma International GmbH, Langen, Germany.

Abstract

BACKGROUND:

Ebola virus (EBOV) and Middle East respiratory syndrome coronavirus (MERS-CoV) have been identified as potential threats to blood safety. This study investigated the efficacy of the THERAFLEX UV-Platelets and THERAFLEX MB-Plasma pathogen inactivation systems to inactivate EBOV and MERS-CoV in platelet concentrates (PCs) and plasma, respectively.

STUDY DESIGN AND METHODS:

PCs and plasma were spiked with high titers of cell culture-derived EBOV and MERS-CoV, treated with various light doses of ultraviolet C (UVC; THERAFLEX UV-Platelets) or methylene blue (MB) plus visible light (MB/light; THERAFLEX MB-Plasma), and assessed for residual viral infectivity.

RESULTS:

UVC reduced EBOV (≥4.5 log) and MERS-CoV (≥3.7 log) infectivity in PCs to the limit of detection, and MB/light decreased EBOV (≥4.6 log) and MERS-CoV (≥3.3 log) titers in plasma to nondetectable levels.

CONCLUSIONS:

Both THERAFLEX UV-Platelets (UVC) and THERAFLEX MB-Plasma (MB/light) effectively reduce EBOV and MERS-CoV infectivity in platelets and plasma, respectively.

PMID:
29732571
DOI:
10.1111/trf.14652
[Indexed for MEDLINE]