Evaluation of analytical similarity between trastuzumab biosimilar CT-P6 and reference product using statistical analyses

MAbs. 2018 May/Jun;10(4):547-571. doi: 10.1080/19420862.2018.1440170. Epub 2018 Mar 14.

Abstract

The evaluation of analytical similarity has been a challenging issue for the biosimilar industry because the number of lots for reference and biosimilar products available at the time of development are limited, whilst measurable quality attributes of target molecule are numerous, which can lead to potential bias or false negative/positive conclusions regarding biosimilarity. Therefore, appropriate statistical analyses are highly desirable to achieve a high level of confidence in the similarity evaluation. A recent guideline for the risk-based statistical approaches recommended by the US Food and Drug Administration provides useful tools to systematically evaluate analytical similarity of biosimilar products compared with reference products. Here, we evaluated analytical similarity of CT-P6, a biosimilar product of trastuzumab, with the reference products (EU-Herceptin® or US-Herceptin®) following these statistical approaches. Various quality attributes of trastuzumab were first ranked based on the clinical impact of each attribute and subsequently adjusted to one of three tiers (Tier 1, Tier 2 and Tier 3) considering the characteristics of the assay, the level of attribute present and the feasibility of statistical analysis. Two biological activities with highest potential clinical impact were evaluated by an equivalent test (Tier 1), and other bioactivities and structural/physicochemical properties relevant to the clinical impact were evaluated by a quality range approach (Tier 2). The attributes with low risk ranking or qualitative assay were evaluated by visual comparison (Tier 3). Analytical similarity assessment analyzed by the three tiers clearly demonstrated that CT-P6 exhibits highly similar structural and physicochemical properties, as well as functional activities, compared with the reference products. There were small differences observed in a few quality attributes between CT-P6 and the reference products, but the differences were very minor, and unlikely to impact on clinical outcome. The recently reported equivalent clinical efficacy of CT-P6 with the reference product further supports that CT-P6 is highly similar compared with the reference product in the view of totality-of-evidence.

Keywords: CT-P6; HerzumaTM; biosimilar; reference product; statistical analyses; trastuzumab.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Biosimilar Pharmaceuticals / chemistry*
  • Biosimilar Pharmaceuticals / standards
  • Humans
  • Reference Standards
  • Trastuzumab / chemistry*

Substances

  • Biosimilar Pharmaceuticals
  • CT-P6
  • Trastuzumab

Grants and funding

This work was suppported by the Celltrion Inc.