Format

Send to

Choose Destination
Anal Chem. 2017 Nov 21;89(22):12562-12568. doi: 10.1021/acs.analchem.7b03837. Epub 2017 Nov 7.

Tandem Femto- and Nanomolar Analysis of Two Protein Biomarkers in Plasma on a Single Mixed Antibody Monolayer Surface Using Surface Plasmon Resonance.

Author information

1
Department of Chemistry and Green-Nano Materials Research Center, Kyungpook National University , 80 Daehakro, Buk-gu, Daegu-city 41566, Republic of Korea.
2
Bio-Medical IT Convergence Research Division, SW Contents Research Laboratory, Electronics and Telecommunications Research Institute , 218 Gajeongno, Yuseong-gu, Daejeon 34129, Republic of Korea.
3
Centre for Molecular Nanometrology, WestCHEM, Department of Pure and Applied Chemistry, Technology and Innovation Centre, University of Strathclyde , 99 George Street, Glasgow G1 1RD, United Kingdom.

Abstract

The multiplexed detection of protein biomarkers in plasma present over a range of clinically relevant concentrations continues to be difficult for surface-based bioaffinity detection platforms such as surface plasmon resonance (SPR). As well as nonspecific adsorption, challenges include quantitative comparison between targets whose concentrations differ by orders of magnitude, regenerating SPR chips after plasma exposure, and the two- or four-channel limitation of many commercial SPR instruments limiting sample throughput. In this article, we explore an approach where two protein biomarkers alpha-1 antitrypsin (AAT) and Tau 381 are detected in tandem within a single SPR channel at micromolar and femtomolar concentrations, respectively. This was achieved by creating a mixed antibody (antiAAT and antiTau) monolayer on the chip surface. After the adsorption of AAT and/or Tau, further specificity was obtained via the adsorption of a DNA aptamer specific to each target. The detection range for each target was controlled via the relative surface density ratio of each antibody type as well as each aptamer concentration. Calibration measurements were performed in both buffer and spiked plasma with the detection of native concentrations of ∼39 fM (Tau) and ∼65 μM (AAT) in a human plasma sample. Finally, tandem measurements of both targets within the same SPR signal channel were demonstrated at these very different concentrations.

PMID:
29065688
DOI:
10.1021/acs.analchem.7b03837
[Indexed for MEDLINE]
Free full text

Supplemental Content

Full text links

Icon for American Chemical Society Icon for Strathprints - the University of Strathclyde
Loading ...
Support Center