JACC Cardiovasc Interv. 2017 Nov 27;10(22):2297-2303. doi: 10.1016/j.jcin.2017.06.037. Epub 2017 Sep 13.

Cerebral Embolic Protection During Transcatheter Aortic Valve Replacement Significantly Reduces Death and Stroke Compared With Unprotected Procedures.

Author information

1
Department of Internal Medicine II, Cardiology, University of Ulm, Ulm, Germany.
2
Department of Neurology, University of Ulm, Ulm, Germany.
3
Department of Internal Medicine II, Cardiology, University of Ulm, Ulm, Germany. Electronic address: jochen.woehrle@uniklinik-ulm.de.

Abstract

OBJECTIVES:

The aim of this study was to evaluate the impact of cerebral embolic protection on stroke-free survival in patients undergoing transcatheter aortic valve replacement (TAVR).

BACKGROUND:

Imaging data on cerebral embolic protection devices have demonstrated a significant reduction in number and volume of cerebral lesions.

METHODS:

A total of 802 consecutive patients were enrolled. The Sentinel cerebral embolic protection device (Claret Medical Inc., Santa Rosa, California) was used in 34.9% (n = 280) of consecutive patients. In 65.1% (n = 522) of patients TAVR was performed in the identical setting except without cerebral embolic protection. Neurological follow-up was done within 7 days post-procedure. The primary endpoint was a composite of all-cause mortality or all-stroke according to Valve Academic Research Consortium-2 criteria within 7 days. Propensity score matching was performed to account for possible confounders.

RESULTS:

Both filters of the device were successfully positioned in 280 of 305 (91.8%) consecutive patients. With use of cerebral embolic protection rate of disabling and nondisabling stroke was significantly reduced from 4.6% to 1.4% (p = 0.03; odds ratio: 0.29, 95% confidence interval: 0.10 to 0.93) in the propensity-matched population (n = 560). The primary endpoint occurred significantly less frequently, with 2.1% (n = 6 of 280) in the protected group compared with 6.8% (n = 19 of 280) in the control group (p = 0.01; odds ratio: 0.30; 95% confidence interval: 0.12 to 0.77). In multivariable analysis Society of Thoracic Surgeons score for mortality (p = 0.02) and TAVR without protection (p = 0.02) were independent predictors for the primary endpoint.

CONCLUSIONS:

In patients undergoing TAVR use of a cerebral embolic protection device demonstrated a significant higher rate of stroke-free survival compared with unprotected TAVR.

KEYWORDS:

TAVR; cerebral embolic protection; outcome; stroke