Mater Sci Eng C Mater Biol Appl. 2017 Dec 1;81:443-451. doi: 10.1016/j.msec.2017.08.019. Epub 2017 Aug 3.

PEGylated stereocomplex polylactide coating of stent for upregulated biocompatibility and drug storage.

Author information

1
Department of Cardiology, The Second Hospital of Jilin University, Changchun 130041, PR China.
2
Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, PR China.
3
State Key Laboratory of Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, PR China.
4
Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, PR China; College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu 610065, PR China.
5
Department of Cardiology, The Second Hospital of Jilin University, Changchun 130041, PR China. Electronic address: liubin3333@vip.sina.com.

Abstract

Treatment of coronary heart disease by percutaneous coronary intervention (PCT) is usually limited to the high restenosis rate after implantation of bare-metal stent. To solve the problem, the coating of PEGylated stereocomplex poly(l-lactide) (PEG-cPLA) was utilized on the surface modification of stainless steel (SS) sheet. Specifically, the 3-aminopropyltriethoxysilane (APTES)-modified methoxy-poly(ethylene glycol)-poly(d-lactide) (mPEG-PDLA) was grafted onto the surface of hydroxylated SS sheet through coupling reaction, and poly(l-lactide)-poly(ethylene glycol)-poly(l-lactide) (PLLA-PEG-PLLA) was coated onto the surface through stereocomplex interaction between DLA and LLA units. The increase of contact angle firstly confirmed the changes of surface composition and hydrophilicity for the PEG-scPLA-modified SS sheet. The decreased fibrinogen adsorption, down-regulated platelet activation, and improved adhesion of human umbilical vein endothelial cells (HUVECs) indicated the excellent biocompatibility of PEG-scPLA-modified SS sheet. In addition, the drug loading capability of SS sheet was greatly upregulated through the formation of scPLA coating on the surface, where fluorescein (FLU) was chosen as a model molecule. Overall, the surface modification of SS sheet with PEG-scPLA could enhance the comprehensive performances, such as biocompatibility and drug loading capability, demonstrating that PEG-scPLA is a promising coating of coronary stent for PCT.

KEYWORDS:

Biocompatibility; Coronary stent; Drug reservoir; Polylactide; Surface coating