Preparation of exenatide-loaded linear poly(ethylene glycol)-brush poly(l-lysine) block copolymer: potential implications on diabetic nephropathy

Int J Nanomedicine. 2017 Jun 29:12:4663-4678. doi: 10.2147/IJN.S136646. eCollection 2017.

Abstract

The poly(ethylene glycol)-b-brush poly(l-lysine) polymer (PEG-b-(PELG50-g-PLL3)) was synthesized and evaluated as a nanocarrier for prolonging delivery of exenatide through the abdominal subcutaneous injection route. The isoelectric point of exenatide was 4.86, and exenatide could combine with PEG-b-(PELG50-g-PLL3) polymers via electrostatic interactions at pH 7.4. This polymer was a good candidate for achieving prolonged drug delivery for exenatide, considering its high molecular weight. Besides the physicochemical characterization of the polymer, in vitro and in vivo applications were researched as a sustained exenatide delivery system. In the in vitro release research, 20.16%-76.88% of total exenatide was released from the PEG-b-(PELG50-g-PLL3) polymer within 7 days. The synthesized block-brush polymers and exenatide-block-brush polymers were analyzed by nuclear magnetic resonance spectroscopy, gel permeation chromatography, transmission electron microscopy, nanoparticle size instrument, and scanning electron microscopy. The best formulation was selected for in vivo experimentation to achieve blood glucose control in diabetic rat models using free exenatide as the control. The hypoglycemic action of the formulation following subcutaneous injection in diabetic rats lasted 7 days, and the results indicated that exenatide-block-brush polymers demonstrate enhanced long-acting hypoglycemic action. Besides the hypoglycemic action, exenatide-block-brush polymers significantly alleviated diabetic nephropathy via improving renal function, decreasing oxidative stress injury, decreasing urinary albumin excretion rate, mitigating albumin/creatinine ratio, reducing blood lipids, abating kidney index, weakening apoptosis, and downregulating expression of connective tissue growth factor. All of the results suggested that PEG-b-(PELG50-g-PLL3) polymers could be used as potential exenatide nanocarriers, with efficient encapsulation and sustained release.

Keywords: PELG50-g-PLL3; block copolymer; diabetic nephropathy; exenatide; hypoglycemic action.

MeSH terms

  • Animals
  • Blood Glucose / metabolism
  • Chromatography, Gel
  • Diabetes Mellitus, Experimental / drug therapy
  • Diabetic Nephropathies / drug therapy*
  • Drug Delivery Systems / methods*
  • Drug Liberation
  • Exenatide
  • Hypoglycemic Agents / administration & dosage*
  • Hypoglycemic Agents / chemistry
  • Hypoglycemic Agents / pharmacology
  • Male
  • Microscopy, Electron, Transmission
  • Nanoparticles / chemistry
  • Peptides / administration & dosage*
  • Peptides / chemistry
  • Peptides / pharmacology
  • Polyethylene Glycols / chemistry
  • Polylysine / chemistry
  • Polymers / chemistry
  • Rats, Sprague-Dawley
  • Venoms / administration & dosage*
  • Venoms / chemistry
  • Venoms / pharmacology

Substances

  • Blood Glucose
  • Hypoglycemic Agents
  • Peptides
  • Polymers
  • Venoms
  • Polylysine
  • Polyethylene Glycols
  • Exenatide