AJR Am J Roentgenol. 2017 Oct;209(4):W221-W230. doi: 10.2214/AJR.16.17325. Epub 2017 Jul 13.

Characterization of Incidental Renal Mass With Dual-Energy CT: Diagnostic Accuracy of Effective Atomic Number Maps for Discriminating Nonenhancing Cysts From Enhancing Masses.

Author information

1
1 Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 NE Pacific St, Seattle, WA 98195.
2
2 Department of Radiology, Duke University Medical Center, Durham, NC.
3
3 Department of Radiology, University of Alabama at Birmingham, Birmingham, AL.
4
4 Department of Biostatistics and Bioinformatics, Duke University School of Medicine, Durham, NC.
5
5 Department of Radiological Sciences, Oncology and Pathology, La Sapienza University of Rome, ICOT Hospital, Latina, Italy.
6
6 Department of Diagnostic, Interventional and Pediatric Radiology, Hospital and University of Bern Inselspital, Bern, Switzerland.

Abstract

OBJECTIVE:

The purpose of this study was to assess the diagnostic accuracy of effective atomic number maps reconstructed from dual-energy contrast-enhanced data for discriminating between nonenhancing renal cysts and enhancing masses.

MATERIALS AND METHODS:

Two hundred six patients (128 men, 78 women; mean age, 64 years) underwent a CT renal mass protocol (single-energy unenhanced and dual-energy contrast-enhanced nephrographic imaging) at two different hospitals. For each set of patients, two blinded, independent observers performed measurements on effective atomic number maps from contrast-enhanced dual-energy data. Renal mass assessment on unenhanced and nephrographic images, corroborated by imaging and medical records, was the reference standard. The diagnostic accuracy of effective atomic number maps was assessed with ROC analysis.

RESULTS:

Significant differences in mean effective atomic numbers (Zeff) were observed between nonenhancing and enhancing masses (set A, 8.19 vs 9.59 Zeff; set B, 8.05 vs 9.19 Zeff; sets combined, 8.13 vs 9.37 Zeff) (p < 0.0001). An effective atomic number value of 8.36 Zeff was the optimal threshold, rendering an AUC of 0.92 (95% CI, 0.89-0.94), sensitivity of 90.8% (158/174 [95% CI, 85.5-94.7%]), specificity of 85.2% (445/522 [95% CI, 81.9-88.2%]), and overall diagnostic accuracy of 86.6% (603/696 [95% CI, 83.9-89.1%]).

CONCLUSION:

Nonenhancing renal cysts, including hyperattenuating cysts, can be discriminated from enhancing masses on effective atomic number maps generated from dual-energy contrast-enhanced CT data. This technique may be of clinical usefulness when a CT protocol for comprehensive assessment of renal masses is not available.

KEYWORDS:

dual-energy CT; effective atomic number; renal cell carcinoma; renal cyst; renal mass