Comparison of Nd: YAG capsulotomy rate between 1-piece and 3-piece acrylic intraocular lenses: A STROBE-compliant article

Medicine (Baltimore). 2017 Jul;96(27):e7444. doi: 10.1097/MD.0000000000007444.

Abstract

The aim of the study is to compare Nd:YAG capsulotomy rate between acrylic 1- and 3-piece intraocular lenses. Among 924 eyes of 762 patients who received cataract surgery, we selected the 303 patients (404 eyes) implanted with an SN60WF 1-piece intraocular lens (Alcon, Fort Worth, TX) or a YA-60BBR 3-piece intraocular lens (Hoya Co., Tokyo, Japan). For intraindividual comparison, we enrolled the 17 patients implanted with an SN60WF in 1 eye and a YA-60BBR in the contralateral eye. We compared Nd:YAG capsulotomy rate between acrylic 1- and 3-piece intraocular lenses 24 months after the operation. Of the 404 eyes in this study, Nd:YAG capsulotomy was performed in 20 of 268 eyes (7.5%) in the SN60WF 1-piece intraocular lens group and 24 of 136 eyes (17.6%) in the YA-60BBR 3-piece intraocular lens group; the difference was statistically significant (P = .002). Among the 17 patients (34 eyes) who were implanted with 2 different inraocular lenses, Nd:YAG capsulotomy was performed in only 2 eyes (12%) in the SN60WF group and 9 eyes (53%) in the YA-60BBR group; the difference was statistically significant (P = .020).The authors found a significantly greater incidence of Nd:YAG capsulotomy in eyes who received 3-piece lenses compared with those who received 1-piece lenses.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Cataract
  • Cataract Extraction
  • Female
  • Follow-Up Studies
  • Humans
  • Laser Therapy
  • Lasers, Solid-State
  • Lens Implantation, Intraocular
  • Lenses, Intraocular / adverse effects*
  • Male
  • Posterior Capsule of the Lens / surgery*
  • Postoperative Complications*
  • Prosthesis Design
  • Retrospective Studies
  • Visual Acuity