Format

Send to

Choose Destination
J Clin Monit Comput. 2018 Apr;32(2):321-326. doi: 10.1007/s10877-017-0029-8. Epub 2017 May 24.

Oral capnography is more effective than nasal capnography during sedative upper gastrointestinal endoscopy.

Author information

1
Department of Anaesthesiology, Taipei Veterans General Hospital and National Yang-Ming University, No. 201, Sec 2, Shipei Rd., Beitou Dist., Taipei City, 11217, Taiwan, ROC.
2
Department of Biomedical Engineering, National Yang-Ming University, No. 155, Sec 2, Linong St., Beitou Dist., Taipei City, 11221, Taiwan, ROC.
3
Department of Medicine, Taipei Veterans General Hospital, No. 201, Sec 2, Shipei Rd., Beitou Dist., Taipei City, 11217, Taiwan, ROC.
4
Department of Biomedical Engineering, National Yang-Ming University, No. 155, Sec 2, Linong St., Beitou Dist., Taipei City, 11221, Taiwan, ROC. hkchiang@ym.edu.tw.
5
Department of Biomedical Engineering, National Yang-Ming University, No. 155, Sec 2, Linong St., Beitou Dist., Taipei City, 11221, Taiwan, ROC. cllin2@ym.edu.tw.

Abstract

The role of capnography in esophagogastroduodenoscopy (EGD) is controversial. Simultaneous supplemental oxygen, position of patient, open mouth breathing pattern, and anatomy of the oral and nasal cavity can influence capnography accuracy. This study first measured capnographic data via the nasal or oral cavity during sedated EGD. Secondly, we investigated the influence of supplementary oxygen through the oral cavity on the capnographic reading. Patients with ASA class I or II status admitted for routine EGD exams were enrolled. End-tidal carbon dioxide measurements were performed simultaneously via nasal catheter and oral catheter with standard oral bite and nasal cannula supplementary oxygen when the patient is awake, during sedation and during sedation with endoscopy. The influence of oral supplementary oxygen, oral capnography were recorded using a mandibular advancement bite block. One hundred and four patients were enrolled. Breathing in the conscious patient is conducted primarily via the nostrils (95%). When sedated with endoscope placement, the percentage of nasal breathing decreased significantly to 47% and oral capnography sufficiently captured data in 100% of patients. Supplementary oral oxygen decreased oral capnographic measurement significantly (38.89 ± 7.148 vs. 30.73 ± 7.84, p < 0.001). However, the measurements using the MA bite block did not differ from oral cavity catheter (28.86 ± 8.51 vs. 30.73 ± 7.839, p = 0.321). The conscious patient breathes mostly nasally while the sedated patient breathes mostly orally during EGD when an oral bite is in place. Capnography measurement via oral cannula increases the measurement accuracy and efficacy. Oral supplementary oxygen may decrease capnographic measurement but still provide sufficient reading for interpretation.

KEYWORDS:

Capnography; Esophagogastroduodenoscopy; Intravenous sedation; Mandibular advancement device

PMID:
28540613
DOI:
10.1007/s10877-017-0029-8

Supplemental Content

Full text links

Icon for Springer
Loading ...
Support Center