Format

Send to

Choose Destination
J Biomed Opt. 2017 May 1;22(5):55002. doi: 10.1117/1.JBO.22.5.055002.

Characterization and correction of the false-discovery rates in resting state connectivity using functional near-infrared spectroscopy.

Author information

1
University of Pittsburgh, Department of Radiology, Pittsburgh, Pennsylvania, United States.
2
Universite de Picardie Jules Verne, Department of Medicine, Amiens, France.
3
University of Pittsburgh, Department of Psychiatry, Pittsburgh, Pennsylvania, United States.
4
University of Pittsburgh, Departments of Radiology and Bioengineering, Clinical Science Translational Institute, and Center for the Neural Basis of Cognition, Pittsburgh, Pennsylvania, United States.

Abstract

Functional near-infrared spectroscopy (fNIRS) is a noninvasive neuroimaging technique that uses low levels of red to near-infrared light to measure changes in cerebral blood oxygenation. Spontaneous (resting state) functional connectivity (sFC) has become a critical tool for cognitive neuroscience for understanding task-independent neural networks, revealing pertinent details differentiating healthy from disordered brain function, and discovering fluctuations in the synchronization of interacting individuals during hyperscanning paradigms. Two of the main challenges to sFC-NIRS analysis are (i) the slow temporal structure of both systemic physiology and the response of blood vessels, which introduces false spurious correlations, and (ii) motion-related artifacts that result from movement of the fNIRS sensors on the participants’ head and can introduce non-normal and heavy-tailed noise structures. In this work, we systematically examine the false-discovery rates of several time- and frequency-domain metrics of functional connectivity for characterizing sFC-NIRS. Specifically, we detail the modifications to the statistical models of these methods needed to avoid high levels of false-discovery related to these two sources of noise in fNIRS. We compare these analysis procedures using both simulated and experimental resting-state fNIRS data. Our proposed robust correlation method has better performance in terms of being more reliable to the noise outliers due to the motion artifacts.

PMID:
28492852
PMCID:
PMC5424771
DOI:
10.1117/1.JBO.22.5.055002
[Indexed for MEDLINE]
Free PMC Article

Supplemental Content

Full text links

Icon for Society of Photo-Optical Instrumentation Engineers Icon for PubMed Central
Loading ...
Support Center