Format

Send to

Choose Destination
Ultrasound Med Biol. 2017 Aug;43(8):1563-1570. doi: 10.1016/j.ultrasmedbio.2017.03.014. Epub 2017 May 5.

Comparison of 2-D Shear Wave Elastography and Transient Elastography for Assessing Liver Fibrosis in Chronic Hepatitis B.

Author information

1
Department of Medical Ultrasonics, Third Affiliated Hospital of Sun Yat-Sen University, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Guangzhou, China.
2
Department of Medical Ultrasonics, Sun Yat-Sen University Tungwah Hospital, Dongguan, China.
3
Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota, USA.
4
Department of Infectious Diseases, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China.
5
Department of Medical Ultrasonics, Third Affiliated Hospital of Sun Yat-Sen University, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Guangzhou, China. Electronic address: zhengrq@mail.sysu.edu.cn.
6
Departments of Hepatobiliary Surgery and Medical Ultrasonics, First Affiliated Hospital of Sun Yat-Sen University, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Guangzhou, China.

Abstract

This study compared 2-D shear wave elastography (SWE) and transient elastography (TE) for liver fibrosis staging in patients with chronic hepatitis B (CHB) infection using liver biopsy as the reference standard. Patients with CHB infection who underwent liver biopsy were consecutively included. After exclusions, 257 patients were analyzed. Two-dimensional SWE resulted in a significantly higher rate of reliable measurements (98.1%, 252/257) than TE (93.0%, 239/257) (p = 0.011). Liver stiffness measurements of the two examinations exhibited a strong correlation (r = 0.835, p < 0.001). In patients given a confirmed histologic diagnosis, Spearman's rank coefficients were 0.520 in stage F0 (p < 0.001), 0.684 in stage F1 (p < 0.001), 0.777 in stage F2 (p < 0.001), 0.672 in stage F3 (p < 0.001) and 0.755 in stage F4 (p < 0.001). There were no significant differences between the areas under the receiver operating characteristic (ROC) curves of 2-D SWE and TE for liver fibrosis staging (all p values > 0.05). Two-dimensional SWE had diagnostic accuracy comparable to that of TE for liver fibrosis staging. The measurements that the two techniques provide are not interchangeable.

KEYWORDS:

2-D shear wave elastography; Hepatitis B; Liver fibrosis; Liver stiffness; Transient elastography