Associations between volume changes and spatial dose metrics for the urinary bladder during local versus pelvic irradiation for prostate cancer

Acta Oncol. 2017 Jun;56(6):884-890. doi: 10.1080/0284186X.2017.1312014. Epub 2017 Apr 12.

Abstract

Background: Inter-fractional variation in urinary bladder volumes during the course of radiotherapy (RT) for prostate cancer causes deviations between planned and delivered doses. This study compared planned versus daily cone-beam CT (CBCT)-based spatial bladder dose distributions, for prostate cancer patients receiving local prostate treatment (local treatment) versus prostate including pelvic lymph node irradiation (pelvic treatment).

Material and methods: Twenty-seven patients (N = 15 local treatment; N = 12 pelvic treatment) were treated using daily image-guided RT (1.8 Gy@43-45 fx), adhering to a full bladder/empty rectum protocol. For each patient, 9-10 CBCTs were registered to the planning CT, using the clinically applied translations. The urinary bladder was manually segmented on each CBCT, 3 mm inner shells were generated, and semi and quadrant sectors were created using axial/coronal cuts. Planned and delivered DVH metrics were compared across patients and between the two groups of treatment (t-test, p < .05; Holm-Bonferroni correction). Associations between bladder volume variations and the dose-volume histograms (DVH) of the bladder and its sectors were evaluated (Spearman's rank correlation coefficient, rs).

Results: Bladder volumes varied considerably during RT (coefficient of variation: 16-58%). The population-averaged planned and delivered DVH metrics were not significantly different at any dose level. Larger treatment bladder volumes resulted in increased absolute volume of the posterior/inferior bladder sector receiving intermediate-high doses, in both groups. The superior bladder sector received less dose with larger bladder volumes for local treatments (rs ± SD: -0.47 ± 0.32), but larger doses for pelvic treatments (rs ± SD: 0.74 ± 0.24).

Conclusions: Substantial bladder volume changes during the treatment course occurred even though patients were treated under a full bladder/daily image-guided protocol. Larger bladder volumes resulted in less bladder wall spared at the posterior-inferior sector, regardless the treatment received. Contrary, larger bladder volumes meant larger delivered doses to the superior bladder sector for pelvic RT but smaller doses for local treatments.

Publication types

  • Comparative Study

MeSH terms

  • Cone-Beam Computed Tomography / methods
  • Humans
  • Image Processing, Computer-Assisted / methods
  • Male
  • Organs at Risk / diagnostic imaging
  • Organs at Risk / pathology
  • Organs at Risk / radiation effects
  • Pelvis / diagnostic imaging
  • Pelvis / pathology*
  • Pelvis / radiation effects
  • Prostate / diagnostic imaging
  • Prostate / pathology*
  • Prostate / radiation effects
  • Prostatic Neoplasms / diagnostic imaging
  • Prostatic Neoplasms / pathology*
  • Prostatic Neoplasms / radiotherapy
  • Radiotherapy Dosage
  • Radiotherapy Planning, Computer-Assisted / methods*
  • Radiotherapy, Image-Guided / methods*
  • Radiotherapy, Intensity-Modulated / methods
  • Rectum / diagnostic imaging
  • Rectum / pathology*
  • Rectum / radiation effects
  • Urinary Bladder / diagnostic imaging
  • Urinary Bladder / pathology*
  • Urinary Bladder / radiation effects