Purpose: To investigate whether a novel method that combines breast imaging reporting and data system (BI-RADS) with strain elastography contributes to diagnostic performance in differentiation of malignant and benign breast lesions.
Methods: In 81 patients, 81 breast lesions were prospectively investigated. Breast lesions were separately evaluated with ultrasonography and strain elastography. While evaluations with ultrasonography were based on 2003 BI-RADS-US, strain elastography evaluations were based on a 5-point scale and strain ratio. Diagnostic performances of ultrasonography, strain elastography, and the combined method were compared.
Results: Among 81 lesions, 43 (53.1%) were benign and 38 (46.9%) were malignant. When a cutoff point of category 3 was used, sensitivity, specificity, positive and negative predictive values, and accuracy for BI-RADS were 100, 11.6, 50, 100, and 53%, respectively. When BI-RADS and strain ratio were combined, sensitivity, specificity, positive and negative predictive values, and accuracy were 89.5, 93, 91.9, 90.9, and 91.3%, respectively. When BI-RADS and elastography scores were combined, sensitivity, specificity, positive and negative predictive values, and accuracy were 86.8, 97.7, 97.1, 89.4, and 92.5%, respectively.
Conclusions: The combination of strain elastography and BI-RADS was found to have better diagnostic performances to diagnose breast lesions than BI-RADS alone.
Keywords: Benign; Breast imaging reporting and data system; Breast lesions; Malignant; Strain elastography.