J Am Heart Assoc. 2017 Feb 1;6(2). pii: e004692. doi: 10.1161/JAHA.116.004692.

Left Ventricular Structure and Function in Relation to Environmental Exposure to Lead and Cadmium.

Author information

1
Studies Coordinating Centre, Research Unit Hypertension and Cardiovascular Epidemiology, KU Leuven Department of Cardiovascular Sciences, University of Leuven, Belgium.
2
Centre for Molecular and Vascular Biology, KU Leuven Department of Cardiovascular Sciences, University of Leuven, Belgium.
3
Centre for Environmental Sciences, University of Hasselt, Belgium.
4
Studies Coordinating Centre, Research Unit Hypertension and Cardiovascular Epidemiology, KU Leuven Department of Cardiovascular Sciences, University of Leuven, Belgium jan.staessen@med.kuleuven.be ja.staessen@maastrichtuniversity.nl.
5
R & D Group VitaK, Maastricht University, Maastricht, The Netherlands.

Abstract

BACKGROUND:

Experimental studies have demonstrated that lead and cadmium have direct toxic effects on the myocardium, but the few human studies are limited by design, assessment of exposure, and use of heart failure as a late-stage endpoint.

METHODS AND RESULTS:

In a prospective population study, we studied the association of left ventricular (LV) function with blood lead (BPb) and 24-hour urinary cadmium (UCd). In 179 participants randomly recruited from a Flemish population (50.3% women; mean age 39.1 years), geometric mean BPb and UCd at enrollment (1985-2000) were 0.20 μmol/L and 6.1 nmol, respectively. We assessed systolic and diastolic LV function 11.9 years (median) later (2005-2010) by using Doppler imaging of the transmitral blood flow and the mitral annular movement and speckle tracking. In multivariable-adjusted linear regression, LV systolic function decreased with BPb. For a doubling of exposure, estimates were -0.392% for global longitudinal strain (P=0.034), -0.618% and -0.113 s-1 for regional longitudinal strain (P=0.028) and strain rate (P=0.008), and -0.056 s-1 for regional radial strain rate (P=0.050). Regional longitudinal strain rate (-0.066 s-1, P=0.009) and regional radial strain (-2.848%, P=0.015) also decreased with UCd. Models including both exposure indexes did not allow differentiating whether LV dysfunction was predominately related to BPb or UCd. Diastolic LV function was not associated with BPb or UCd (P≥0.159).

CONCLUSIONS:

Although effect sizes were small, our results suggest that environmental exposure to lead, cadmium, or both might be a risk factor for systolic LV dysfunction, a condition often proceeding to heart failure.

KEYWORDS:

cadmium; heart failure; lead; population science; systolic function

PMID:
28151401
PMCID:
PMC5523767
DOI:
10.1161/JAHA.116.004692
[Indexed for MEDLINE]
Free PMC Article

Supplemental Content

Full text links

Icon for Atypon Icon for PubMed Central
Loading ...