The effects of sterilization on the accuracy of silicone ear impression materials

Scand Audiol. 1989;18(3):131-3. doi: 10.3109/01050398909070735.

Abstract

The dimensional stability of a range of elastomeric impression materials has been assessed to study the effect of storage in sterilizing solutions. Experiments were carried out on audiological silicones of condensation and addition types. Further, a number of dental-based materials comprising a polysulphide, a polyether, a condensation and an addition silicone, were also investigated for comparison. The results indicate that the addition silicones had the greatest dimensional stability over a range of storage conditions, which included aqueous glutaraldehyde and hypochlorite solutions.

MeSH terms

  • Ear, External*
  • Prostheses and Implants*
  • Prosthesis Design
  • Silicone Elastomers*
  • Sterilization*
  • Surface Properties

Substances

  • Silicone Elastomers