Format

Send to

Choose Destination
Circ Res. 2017 Feb 17;120(4):692-700. doi: 10.1161/CIRCRESAHA.116.309738. Epub 2017 Jan 10.

Hemodynamic Support With a Microaxial Percutaneous Left Ventricular Assist Device (Impella) Protects Against Acute Kidney Injury in Patients Undergoing High-Risk Percutaneous Coronary Intervention.

Author information

1
From the Cardiovascular Medicine, University of Louisville School of Medicine, KY (M.P.F., S.P., T.K., S.D., J.H.L., W.R.); Internal Medicine, Sparks Regional Medical Center, Fort Smith, AR (S.V.P.); Cardiology, University of Kansas Medical Center, Kansas City (B.D.); Cardiothoracic Surgery, Washington University School of Medicine, St. Louis, MO (A.C.); and Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia (C.R.B.). mpflah01@louisville.edu.
2
From the Cardiovascular Medicine, University of Louisville School of Medicine, KY (M.P.F., S.P., T.K., S.D., J.H.L., W.R.); Internal Medicine, Sparks Regional Medical Center, Fort Smith, AR (S.V.P.); Cardiology, University of Kansas Medical Center, Kansas City (B.D.); Cardiothoracic Surgery, Washington University School of Medicine, St. Louis, MO (A.C.); and Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia (C.R.B.).

Abstract

RATIONALE:

Acute kidney injury (AKI) is common during high-risk percutaneous coronary intervention (PCI), particularly in those with severely reduced left ventricular ejection fraction. The impact of partial hemodynamic support with a microaxial percutaneous left ventricular assist device (pLVAD) on renal function after high-risk PCI remains unknown.

OBJECTIVE:

We tested the hypothesis that partial hemodynamic support with the Impella 2.5 microaxial pLVAD during high-risk PCI protected against AKI.

METHODS AND RESULTS:

In this retrospective, single-center study, we analyzed data from 230 patients (115 consecutive pLVAD-supported and 115 unsupported matched-controls) undergoing high-risk PCI with ejection fraction ≤35%. The primary outcome was incidence of in-hospital AKI according to AKI network criteria. Logistic regression analysis determined the predictors of AKI. Overall, 5.2% (6) of pLVAD-supported patients versus 27.8% (32) of unsupported control patients developed AKI (P<0.001). Similarly, 0.9% (1) versus 6.1% (7) required postprocedural hemodialysis (P<0.05). Microaxial pLVAD support during high-risk PCI was independently associated with a significant reduction in AKI (adjusted odds ratio, 0.13; 95% confidence intervals, 0.09-0.31; P<0.001). Despite preexisting CKD or a lower ejection fraction, pLVAD support protection against AKI persisted (adjusted odds ratio, 0.63; 95% confidence intervals, 0.25-0.83; P=0.04 and adjusted odds ratio, 0.16; 95% confidence intervals, 0.12-0.28; P<0.001, respectively).

CONCLUSIONS:

Impella 2.5 (pLVAD) support protected against AKI during high-risk PCI. This renal protective effect persisted despite the presence of underlying CKD and decreasing ejection fraction.

KEYWORDS:

acute kidney injury; hemodynamic support; left ventricular dysfunction; percutaneous coronary intervention; ventricular assist device

PMID:
28073804
DOI:
10.1161/CIRCRESAHA.116.309738
[Indexed for MEDLINE]