Format

Send to

Choose Destination
J Pediatr. 2017 Mar;182:41-46.e2. doi: 10.1016/j.jpeds.2016.11.014. Epub 2016 Dec 6.

Oxygen Saturation and Heart Rate Ranges in Very Preterm Infants Requiring Respiratory Support at Birth.

Author information

1
Centre for the Studies of Asphyxia and Resuscitation, Royal Alexandra Hospital, Edmonton, Alberta, Canada.
2
Centre for the Studies of Asphyxia and Resuscitation, Royal Alexandra Hospital, Edmonton, Alberta, Canada; Department of Pediatrics, University of Alberta, Edmonton, Alberta, Canada; Department of Pediatric and Adolescent Medicine, Akershus University Hospital, Lørenskog, Norway.
3
Centre for the Studies of Asphyxia and Resuscitation, Royal Alexandra Hospital, Edmonton, Alberta, Canada; Department of Pediatrics, University of Alberta, Edmonton, Alberta, Canada.
4
Centre for the Studies of Asphyxia and Resuscitation, Royal Alexandra Hospital, Edmonton, Alberta, Canada; Department of Pediatrics, Medical University Graz, Graz, Austria.
5
Centre for the Studies of Asphyxia and Resuscitation, Royal Alexandra Hospital, Edmonton, Alberta, Canada; Department of Physiology, University of Alberta, Edmonton, Alberta, Canada.

Abstract

OBJECTIVE:

To evaluate the changes in preductal oxygen saturation (SpO2) and heart rate in preterm infants receiving continuous positive airway pressure (CPAP) and/or positive-pressure ventilation (PPV) at birth.

STUDY DESIGN:

A prospective observational study at birth of infants aged <32 weeks separated into 2 gestational age (GA) groups: 230/7-276/7 weeks (group 1) and 280/7-316/7 weeks (group 2). Infants received delayed cord clamping (DCC) in accordance with institutional protocol. CPAP and/or PPV was applied at the clinical team's discretion. SpO2 and heart rate were recorded every minute for 10 minutes. Preductal SpO2 was targeted according to published nomograms. For heart rate, the goal was to maintain a stable heart rate >100 bpm.

RESULTS:

The study cohort comprised 96 group 1 infants (mean GA, 26 ± 1 weeks; mean birth weight, 818 ± 208 g) and 173 group 2 infants (mean GA, 30 ± 1 weeks; mean birth weight, 1438 ± 374 g). In general, infants requiring respiratory support reached target values for heart rate and SpO2 more slowly than the published nomograms for spontaneously breathing preterm infants without respiratory support. Infants receiving CPAP reached SpO2 and heart rate targets faster than infants receiving PPV. In group 1, but not group 2 infants, DCC resulted in higher SpO2 and heart rate.

CONCLUSION:

SpO2 and heart rate do not quickly and reliably reach the values achieved by spontaneously breathing preterm infants not requiring respiratory support.

KEYWORDS:

heart rate; infants; neonatal; newborn; oxygen saturation; pulse oximetry; resuscitation

PMID:
27939259
DOI:
10.1016/j.jpeds.2016.11.014
[Indexed for MEDLINE]

Supplemental Content

Full text links

Icon for Elsevier Science
Loading ...
Support Center