Format

Send to

Choose Destination
PLoS One. 2016 Aug 11;11(8):e0160644. doi: 10.1371/journal.pone.0160644. eCollection 2016.

An Activity Index for Raw Accelerometry Data and Its Comparison with Other Activity Metrics.

Author information

1
Department of Biostatistics, Johns Hopkins University, Baltimore, Maryland, United States of America.
2
Division of Public Health Sciences, Fred Hutchinson Cancer Research Center, Seattle, Washington, United States of America.
3
Department of Statistics, North Carolina State University at Raleigh, Raleigh, North Carolina, United States of America.
4
Department of Epidemiology, Gillings School of Global Public Health, University of North Carolina-Chapel Hill, Chapel Hill, North Carolina, United States of America.
5
Division of Epidemiology, Department of Family Medicine and Public Health, University of California San Diego, La Jolla, California, United States of America.
6
Department of Kinesiology and Community Health, University of Illinois at Urbana-Champaign, Champaign, Illinois, United States of America.

Abstract

Accelerometers have been widely deployed in public health studies in recent years. While they collect high-resolution acceleration signals (e.g., 10-100 Hz), research has mainly focused on summarized metrics provided by accelerometers manufactures, such as the activity count (AC) by ActiGraph or Actical. Such measures do not have a publicly available formula, lack a straightforward interpretation, and can vary by software implementation or hardware type. To address these problems, we propose the physical activity index (AI), a new metric for summarizing raw tri-axial accelerometry data. We compared this metric with the AC and another recently proposed metric for raw data, Euclidean Norm Minus One (ENMO), against energy expenditure. The comparison was conducted using data from the Objective Physical Activity and Cardiovascular Health Study, in which 194 women 60-91 years performed 9 lifestyle activities in the laboratory, wearing a tri-axial accelerometer (ActiGraph GT3X+) on the hip set to 30 Hz and an Oxycon portable calorimeter, to record both tri-axial acceleration time series (converted into AI, AC, and ENMO) and oxygen uptake during each activity (converted into metabolic equivalents (METs)) at the same time. Receiver operating characteristic analyses indicated that both AI and ENMO were more sensitive to moderate and vigorous physical activities than AC, while AI was more sensitive to sedentary and light activities than ENMO. AI had the highest coefficients of determination for METs (0.72) and was a better classifier of physical activity intensity than both AC (for all intensity levels) and ENMO (for sedentary and light intensity). The proposed AI provides a novel and transparent way to summarize densely sampled raw accelerometry data, and may serve as an alternative to AC. The AI's largely improved sensitivity on sedentary and light activities over AC and ENMO further demonstrate its advantage in studies with older adults.

PMID:
27513333
PMCID:
PMC4981309
DOI:
10.1371/journal.pone.0160644
[Indexed for MEDLINE]
Free PMC Article

Supplemental Content

Full text links

Icon for Public Library of Science Icon for PubMed Central
Loading ...
Support Center