Format

Send to

Choose Destination
Clin Radiol. 2016 Nov;71(11):1120-5. doi: 10.1016/j.crad.2016.06.114. Epub 2016 Jul 18.

Covered airway stent placement for malignant tracheobronchial strictures in patients with an endotracheal tube.

Author information

1
Departments of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap 2-dong, Songpa-gu, Seoul, 138-736, Republic of Korea.
2
Departments of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap 2-dong, Songpa-gu, Seoul, 138-736, Republic of Korea. Electronic address: jhshin@amc.seoul.kr.

Abstract

AIM:

To evaluate the technical feasibility and safety of covered airway stent placement for malignant tracheobronchial strictures in patients with an endotracheal tube.

MATERIALS AND METHODS:

Data regarding retrievable, expandable, metal stent placement under fluoroscopic guidance in 20 patients with an endotracheal tube inserted for malignant tracheobronchial strictures were retrospectively analysed. The clinical effectiveness was assessed using the following variables: technical and clinical success; procedure and stent-related complications; and duration of intubation following stent placement.

RESULTS:

Stent placement was technically successful in all 20 patients (100%), and with 19 of the 20 patients (95%) showing symptomatic improvement within 5 days. The endotracheal tube could be removed during (n=7) or after (n=12) stent placement, and the mean duration of intubation following stent placement was 1.4 days (range 0-3 days). One patient could not have his endotracheal tube removed and he died 9 days following stent placement in an intubated state. There were no procedure-related complications. Stent-related complications in three patients included partial (n=2) and complete (n=1) stent migration, all of which were managed with placement of a second stent (n=2) or stent removal and placement of a second stent (n=1).

CONCLUSION:

Covered airway stent placement under fluoroscopic guidance in patients with an endotracheal tube inserted for malignant tracheobronchial strictures, is both technically feasible and safe.

PMID:
27444409
DOI:
10.1016/j.crad.2016.06.114
[Indexed for MEDLINE]