Format

Send to

Choose Destination
Science. 1989 Jun 16;244(4910):1328-33.

Bright light induction of strong (type 0) resetting of the human circadian pacemaker.

Author information

1
Department of Medicine, Harvard Medical School, Brigham and Women's Hospital, Boston, MA 02115.

Abstract

The response of the human circadian pacemaker to light was measured in 45 resetting trials. Each trial consisted of an initial endogenous circadian phase assessment, a three-cycle stimulus which included 5 hours of bright light per cycle, and a final phase assessment. The stimulus induced strong (type 0) resetting, with responses highly dependent on the initial circadian phase of light exposure. The magnitude and direction of the phase shifts were modulated by the timing of exposure to ordinary room light, previously thought to be undetectable by the human pacemaker. The data indicate that the sensitivity of the human circadian pacemaker to light is far greater than previously recognized and have important implications for the therapeutic use of light in the management of disorders of circadian regulation.

PMID:
2734611
DOI:
10.1126/science.2734611
[Indexed for MEDLINE]