J Comput Assist Tomogr. 2016 Sep-Oct;40(5):806-14. doi: 10.1097/RCT.0000000000000442.

Dual-Energy CT Characteristics of Parathyroid Adenomas on 25-and 55-Second 4D-CT Acquisitions: Preliminary Experience.

Author information

1
From the *Department of Radiology, †Segal Cancer Centre, ‡Lady Davis Institute for Medical Research, and §Department of Otolaryngology-Head and Neck Surgery, Jewish General Hospital, McGill University, Montreal, Quebec, Canada; and ‖Lineberger Comprehensive Cancer Center, University of North Carolina, Chapel Hill, NC.

Abstract

OBJECTIVE:

The objective of this study was to compare the dual-energy computed tomography (CT) characteristics of parathyroid adenomas (PAs), thyroid tissue, and lymph nodes (LNs) and assess whether the spectral information can improve distinction of these tissues.

METHODS:

Dual-energy CT scans from 20 patients with pathologically proven PAs were retrospectively evaluated, identifying 19 eligible PAs and region of interest analysis used for spectral characterization.

RESULTS:

There was a significant difference in multiple spectral parameters between PAs, LNs, and the thyroid gland (P < 0.05-0.0001). The greatest difference in spectral characteristics of PAs compared with that of LNs was on the 25-second acquisition, whereas the 55-second acquisition was better for distinguishing PAs from the thyroid gland.

CONCLUSIONS:

Four-dimensional CT acquired in dual-energy CT mode has the potential to further enhance diagnostic accuracy for PA identification on individual phases of the perfusion study.

PMID:
27224226
DOI:
10.1097/RCT.0000000000000442
[Indexed for MEDLINE]