Format

Send to

Choose Destination
Medicine (Baltimore). 2016 Apr;95(16):e3428. doi: 10.1097/MD.0000000000003428.

Development of the A-DIVA Scale: A Clinical Predictive Scale to Identify Difficult Intravenous Access in Adult Patients Based on Clinical Observations.

Author information

1
From the Department of Anesthesiology (FHJL, LAPMP, ARAB), Catharina Hospital Eindhoven, The Netherlands; Department of Research and Education (FHJL, SH), Catharina Hospital Eindhoven, The Netherlands; Fontys University of Applied Sciences (FHJL), Eindhoven, The Netherlands; Department of Signal Processing Systems and Electrical Enginereering (ARAB), TU/e University of Technology, Eindhoven, The Netherlands.

Abstract

Placement of a peripheral intravenous catheter is a routine procedure in clinical practice, but failure of intravenous cannulation regularly occurs. An accurate and reliable predictive scale for difficult venous access creates the possibility to use other techniques in an earlier time frame. We aimed to develop a predictive scale to identify adult patients with a difficult intravenous access prospectively: the A-DIVA scale. This prospective, observational, cross-sectional cohort study was conducted between January 2014 and January 2015, and performed at the department of anesthesiology of the Catharina Hospital (Eindhoven, The Netherlands). Patients 18 years or older were eligible if scheduled for any surgical procedure, regardless ASA classification, demographics, and medical history. Experienced and certified anesthesiologists and nurse anesthetists routinely obtained peripheral intravenous access. Cannulation was performed regarding standards for care. A failed peripheral intravenous cannulation on the first attempt was the outcome of interest. A population-based sample of 1063 patients was included. Failure of intravenous cannulation was observed in 182/1063 patients (17%). Five variables were associated with a failed first attempt of peripheral intravenous cannulation: palpability of the target vein (OR = 4.94, 95% CI [2.85-8.56]; P < 0.001), visibility of the target vein (OR = 3.63, 95% CI [2.09-6.32]; P < 0.001), a history of difficult peripheral intravenous cannulation (OR = 3.86, 95% CI [2.39-6.25]; P < 0.001), an unplanned indication for surgery (OR = 4.86, 95% CI [2.92-8.07]; P < 0.001), and the vein diameter of at most 2 millimeters (OR = 3.37, 95% CI [2.12-5.36]; P < 0.001). The scoring system was applied in 3 risk groups: 36/788 patients (5%) suffered from a failed first attempt in the low-risk group (A-DIVA score 0 or 1), whereas the medium (A-DIVA score 2 or 3) and high-risk group (A-DIVA score 4 plus), included 72/195 (37%) and 74/80 (93%) patients with a failed first attempt of inserting a peripheral intravenous catheter, respectively. The additive 5-variable A-DIVA scale is a reliable predictive rule that implies the probability to identify patients with a difficult intravenous access prospectively. Dutch Trial Register (ref: 4595).

PMID:
27100437
PMCID:
PMC4845841
DOI:
10.1097/MD.0000000000003428
[Indexed for MEDLINE]
Free PMC Article

Supplemental Content

Full text links

Icon for Wolters Kluwer Icon for PubMed Central
Loading ...
Support Center