Shear Wave Elastography of the Spleen for Monitoring Transjugular Intrahepatic Portosystemic Shunt Function: A Pilot Study

J Ultrasound Med. 2016 May;35(5):951-8. doi: 10.7863/ultra.15.07009. Epub 2016 Apr 1.

Abstract

Objectives: To assess the feasibility of splenic shear wave elastography in monitoring transjugular intrahepatic portosystemic shunt (TIPS) function.

Methods: We measured splenic shear wave velocity (SWV), main portal vein velocity (PVV), and splenic vein velocity (SVV) in 33 patients 1 day before and 3 days to 12 months after TIPS placement. We also measured PVV, SVV, and SWV in 10 of 33 patients with TIPS dysfunction 1 day before and 3 to 6 days after TIPS revision. Analyses included differences in portosystemic pressure gradient (PPG), PVV, SVV, and mean SWV before and after TIPS procedures; comparison of median SWV before and after TIPS procedures; differences in PVV, SVV, and SWV before and at different times up to 12 months after TIPS placement; accuracy of PVV, SVV, and SWV in determining TIPS dysfunction; and correlation between PPG and SWV.

Results: During 12 months of follow-up, 23 of 33 patients had functioning TIPS, and 10 had TIPS dysfunction. The median SWV was significantly different before and after primary TIPS placement (3.60 versus 3.05 m/s; P = .005), as well as before and after revision (3.73 versus 3.06 m/s; P = .003). The PPG, PVV, and SVV were also significantly different before and after TIPS placement and revision (P < .001). The PPG and SWV decreased, whereas PVV and SVV increased, after successful TIPS procedures. A positive correlation was observed between PPG and SWV (r = 0.70; P < .001), and a negative correlation was observed between PPG and PVV and SVV (r = -0.65; P < .001). The areas under the receiver operating characteristic curve for PVV, SVV, and SWV in determining TIPS dysfunction were 0.82, 0.84, and 0.81, respectively.

Conclusions: Splenic SWV is compatible with splenoportal venous velocity in quantitatively monitoring TIPS function and determining TIPS dysfunction.

Keywords: Doppler sonography; shear wave velocity; spleen stiffness; transjugular intrahepatic portosystemic shunt; ultrasound elastography.

MeSH terms

  • Adult
  • Aged
  • Blood Flow Velocity
  • Elasticity Imaging Techniques / methods*
  • Feasibility Studies
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Pilot Projects
  • Portasystemic Shunt, Transjugular Intrahepatic*
  • Postoperative Complications / diagnostic imaging*
  • ROC Curve
  • Spleen / diagnostic imaging*