Adult Heart Transplantation Following Ventricular Assist Device Implantation: Early and Late Outcomes

Transplant Proc. 2016 Jan-Feb;48(1):158-66. doi: 10.1016/j.transproceed.2015.12.007.

Abstract

Purpose: The impact of prior implantation of a ventricular assist device (VAD) on short- and long-term postoperative outcomes of adult heart transplantation (HTx) was investigated.

Methods: Of the 359 adults with prior cardiac surgery who underwent HTx from December 1988 to June 2012 at our institution, 90 had prior VAD and 269 had other (non-VAD) prior cardiac surgery.

Results: The VAD group had a lower 60-day survival when compared with the Non-VAD group (91.1% ± 3.0% vs 96.6% ± 1.1%; P = .03). However, the VAD and Non-VAD groups had similar survivals at 1 year (87.4% ± 3.6% vs 90.5% ± 1.8%; P = .33), 2 years (83.2% ± 4.2% vs 88.1% ± 2.0%; P = .21), 5 years (75.7% ± 5.6% vs 74.6% ± 2.9%; P = .63), 10 years (38.5% ± 10.8% vs 47.6% ± 3.9%; P = .33), and 12 years (28.9% ± 11.6% vs 39.0% ± 4.0%; P = .36). The VAD group had longer pump time and more intraoperative blood use when compared with the Non-VAD group (P < .0001 for both). Postoperatively, VAD patients had higher frequencies of >48-hour ventilation and in-hospital infections (P = .0007 and .002, respectively). In addition, more VAD patients had sternal wound infections when compared with Non-VAD patients (8/90 [8.9%] vs 5/269 [1.9%]; P = .005). Both groups had similar lengths of intensive care unit (ICU) and hospital stays and no differences in the frequencies of reoperation for chest bleeding, dialysis, and postdischarge infections (P = .19, .70, .34, .67, and .21, respectively). Postoperative creatinine levels at peak and at discharge did not differ between the 2 groups (P = .51 and P = .098, respectively). In a Cox model, only preoperative creatinine ≥1.5 mg/dL (P = .006) and intraoperative pump time ≥210 minutes (P = .022) were individually considered as significant predictors of mortality within 12 years post-HTx. Adjusting for both, pre-HTx VAD implantation was not a predictor of mortality within 12 years post-HTx (hazard ratio [HR], 1.23; 95% confidence interval [CI], 0.77-1.97; P = .38). However, pre-HTx VAD implantation was a risk factor for 60-day mortality (HR, 2.86; 95% CI, 1.07-7.62; P = .036) along with preoperative creatinine level ≥2 mg/dL (P = .0006).

Conclusions: HTx patients with prior VAD had lower 60-day survival, higher intraoperative blood use, and greater frequency of postoperative in-hospital infections when compared with HTx patients with prior Non-VAD cardiac surgery. VAD implantation prior to HTx did not have an additional negative impact on long-term morbidity and survival following HTx. Long-term (1-, 2-, 5-, 10-, and 12-year) survival did not differ significantly in HTx patients with prior VAD or non-VAD cardiac surgery.

MeSH terms

  • Adult
  • California / epidemiology
  • Female
  • Heart Failure / mortality
  • Heart Failure / therapy*
  • Heart Transplantation / mortality*
  • Heart-Assist Devices*
  • Humans
  • Length of Stay / trends
  • Male
  • Middle Aged
  • Proportional Hazards Models
  • Risk Factors
  • Survival Rate / trends
  • Time Factors
  • Treatment Outcome