Format

Send to

Choose Destination
Am J Orthop (Belle Mead NJ). 2015 Dec;44(12):542-6.

Technique Using Isoelastic Tension Band for Treatment of Olecranon Fractures.

Author information

1
Department of Orthopedic Surgery, Columbia University College of Physicians and Surgeons, New York, NY. ttc@columbia.edu.

Abstract

The isoelastic ultrahigh-molecular-weight polyethylene tension band may be considered an alternative to stainless steel wire for tension band fixation of olecranon fractures. In this article, we present our technique using this isoelastic tension band and describe the outcomes of 7 patients who underwent open reduction and internal fixation of closed, displaced olecranon fractures with minimal or no articular surface comminution. We reviewed medical records and performed physical examinations and functional assessments. Anatomical reduction was maintained in all elbows through union. Physical examination measurements indicated nominal side-to-side differences in motion and strength. Mean Broberg and Morrey elbow score was good (92/100), and mean (SD) Disabilities of the Arm, Shoulder, and Hand score was 12.6 (17.2). One patient had a minor degree of hardware irritation at longest follow-up but did not request hardware removal. One patient underwent implant removal for a symptomatic implant 5 years after surgery. This easily reproducible technique yields excellent physical and functional outcomes.

PMID:
26665240
[Indexed for MEDLINE]

Supplemental Content

Full text links

Icon for Frontline Medical Communications Inc
Loading ...
Support Center