Format

Send to

Choose Destination
PLoS One. 2015 Nov 25;10(11):e0143092. doi: 10.1371/journal.pone.0143092. eCollection 2015.

Impact of Pre-Analytical Variables on Cancer Targeted Gene Sequencing Efficiency.

Author information

1
James Thoracic Center, The Ohio State University Comprehensive Cancer Center, Columbus, Ohio, 43210, United States of America.
2
Department of Biomedical Informatics, The Ohio State University, Columbus, Ohio, 43210, United States of America.
3
GenomOncology, Cleveland, Ohio, 44145, United States of America.
4
Biomedical Informatics Shared Resource, The Ohio State University Comprehensive Cancer Center, Columbus, Ohio, 43210, United States of America.
5
Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.
6
Brazilian National Cancer Institute, Rio de Janeiro, Brazil.

Abstract

Tumor specimens are often preserved as formalin-fixed paraffin-embedded (FFPE) tissue blocks, the most common clinical source for DNA sequencing. Herein, we evaluated the effect of pre-sequencing parameters to guide proper sample selection for targeted gene sequencing. Data from 113 FFPE lung tumor specimens were collected, and targeted gene sequencing was performed. Libraries were constructed using custom probes and were paired-end sequenced on a next generation sequencing platform. A PCR-based quality control (QC) assay was utilized to determine DNA quality, and a ratio was generated in comparison to control DNA. We observed that FFPE storage time, PCR/QC ratio, and DNA input in the library preparation were significantly correlated to most parameters of sequencing efficiency including depth of coverage, alignment rate, insert size, and read quality. A combined score using the three parameters was generated and proved highly accurate to predict sequencing metrics. We also showed wide read count variability within the genome, with worse coverage in regions of low GC content like in KRAS. Sample quality and GC content had independent effects on sequencing depth, and the worst results were observed in regions of low GC content in samples with poor quality. Our data confirm that FFPE samples are a reliable source for targeted gene sequencing in cancer, provided adequate sample quality controls are exercised. Tissue quality should be routinely assessed for pre-analytical factors, and sequencing depth may be limited in genomic regions of low GC content if suboptimal samples are utilized.

PMID:
26605948
PMCID:
PMC4659597
DOI:
10.1371/journal.pone.0143092
[Indexed for MEDLINE]
Free PMC Article

Supplemental Content

Full text links

Icon for Public Library of Science Icon for PubMed Central
Loading ...