Comparison of retraction phenomenon and BI-RADS-US descriptors in differentiating benign and malignant breast masses using an automated breast volume scanner

Eur J Radiol. 2015 Nov;84(11):2123-9. doi: 10.1016/j.ejrad.2015.07.028. Epub 2015 Jul 30.

Abstract

Objective: To compare the diagnostic values of retraction phenomenon in the coronal planes and descriptors in the Breast Imaging Reporting and Data System-Ultrasound (BI-RADS-US) lexicon in differentiating benign and malignant breast masses using an automated breast volume scanner (ABVS).

Materials and methods: Two hundred and eight female patients with 237 pathologically proven breast masses (120 benign and 117 malignant) were included in this study. ABVS was performed for each mass after preoperative localization by conventional ultrasonography (US). Multivariate logistic regression analysis was performed to assess independent variables for malignancy prediction. Diagnostic performance was evaluated through the receiver operating characteristic (ROC) curve analysis.

Results: Retraction phenomenon (odds ratio [OR]: 76.70; 95% confidence interval [CI]: 12.55, 468.70; P<0.001) was the strongest independent predictor for malignant masses, followed by microlobulated margins (OR: 55.87; 95% CI: 12.56, 248.44; P<0.001), angular margins (OR: 36.44; 95% CI: 4.55, 292.06; P=0.001), calcifications (OR: 5.53; 95% CI: 1.34, 22.88; P=0.018,) and patient age (OR: 1.10; 95% CI: 1.03, 1.17; P=0.004). Mass shape, orientation, echo pattern, indistinct margins, spiculated margins, and mass size were not significantly associated with breast malignancy. Area under the ROC curve (Az) for microlobulated margins and retraction phenomenon was higher than that for other significant independent predictors. Az, sensitivity, and specificity were 0.877 (95% CI: 0.829, 0.926) and 0.838 (95% CI: 0.783, 0.892), 82.9% and 70.1%, and 92.5% and 98.3%, respectively, for microlobulated margins and retraction phenomenon.

Conclusions: Retraction phenomenon and microlobulated margins have high diagnostic values in the differentiation of benign and malignant breast masses using an ABVS.

Keywords: Automated breast volume scanner; BI-RADS; Breast mass; Diagnosis; Retraction phenomenon; Ultrasound.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Breast / pathology*
  • Breast Neoplasms / diagnostic imaging
  • Breast Neoplasms / pathology*
  • China / epidemiology
  • Female
  • Humans
  • Image Enhancement
  • Image Interpretation, Computer-Assisted* / instrumentation
  • Image Interpretation, Computer-Assisted* / methods
  • Middle Aged
  • Pattern Recognition, Automated
  • ROC Curve
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Ultrasonography, Mammary / instrumentation*
  • Ultrasonography, Mammary / methods