We report a case of guide wire loss and migration after central venous access for spinal deformity surgery. Guide wire migration was noticed on a follow-up full spine x-ray 69 days postoperatively. Percutaneous retrieval was successfully performed using endovascular techniques. With this case report, we want to highlight the fact that one could miss other pathologies visible on these full spine x-rays when concentrating only on the measurement of spinopelvic parameters.
Keywords: Central venous catheter; Complication; Spinal surgery.
Copyright © 2015 Elsevier Inc. All rights reserved.