Format

Send to

Choose Destination
J Prosthet Dent. 2015 Jul;114(1):46-51. doi: 10.1016/j.prosdent.2014.12.016. Epub 2015 Mar 24.

Prospective, 1-year observational study of double-threaded tapered body dental implants with immediate loading.

Author information

1
Assistant Professor of Clinical Dentistry, Chair of Removable Section, Department of Restorative Science, Herman Ostrow School of Dentistry of USC, University of Southern California, Los Angeles, Calif. Electronic address: thk@usc.edu.
2
Clinical Assistant Professor, Department of Restorative Science, Herman Ostrow School of Dentistry of USC, University of Southern California, Los Angeles, Calif.
3
Professor of Clinical Dentistry, Herman Ostrow School of Dentistry of USC, University of Southern California, Los Angeles, Calif.
4
Associate Professor Emerita, Herman Ostrow School of Dentistry of USC, University of Southern California, Los Angeles, Calif.
5
Research Expert, Italian Ministry of Education and Research; and Chairman, Research Department, Taipei Academy of Reconstructive Dentistry, Taipei, Taiwan.

Abstract

STATEMENT OF PROBLEM:

Unlike conventional loading protocols, the immediate loading of single implants has not been fully investigated.

PURPOSE:

The purpose of this study was to assess the prosthetic and esthetic periimplant mucosal outcomes of immediately restored dental implants during a 1-year follow-up.

MATERIAL AND METHODS:

Twenty participants meeting the established inclusion criteria received double-threaded, tapered body dental implants (SuperLine; Dentium). Implants were placed and stabilized at a minimum of 35 Ncm of torque and restored immediately after the surgery with interim restorations. These were replaced with definitive restorations 6 months after implant placement. Clinical measurements at each visit included resonance frequency analysis, the evaluation of the participants' oral health (gingival and plaque indices), and the esthetic outcome of the interim or definitive restoration.

RESULTS:

Implants placed in this clinical study had a 100% success rate. The oral health and esthetic outcomes were favorable for all participants.

CONCLUSIONS:

Double-threaded, tapered body dental implants that were placed and immediately restored with fixed interim prostheses and with definitive prostheses after 6 months remained stable and functional after 1 year.