Continuous cardiac output measurement by un-calibrated pulse wave analysis and pulmonary artery catheter in patients with septic shock

J Clin Monit Comput. 2016 Feb;30(1):13-22. doi: 10.1007/s10877-015-9672-0. Epub 2015 Feb 27.

Abstract

Septic shock is a serious medical condition. With increased concerns about invasive techniques, a number of non-invasive and semi-invasive devices measuring cardiac output (CO) have become commercially available. The aim of the present study was to determine the accuracy, precision and trending abilities of the FloTrac and the continuous pulmonary artery catheter thermodilution technique determining CO in septic shock patients. Consecutive septic shock patients were included in two centres and CO was measured every 4 h up to 48 h by FloTrac (APCO) and by pulmonary artery catheter (PAC) using the continuous (CCO) and intermittent (ICO) technique. Forty-seven septic shock patients with 326 matched sets of APCO, CCO and ICO data were available for analysis. Bland and Altman analysis revealed a mean bias ±2 SD of 0.0 ± 2.14 L min(-1) for APCO-ICO (%error = 34.5 %) and 0.23 ± 2.55 L min(-1) for CCO-ICO (%error = 40.4 %). Trend analysis showed a concordance of 85 and 81 % for APCO and CCO, respectively. In contrast to CCO, APCO was influenced by systemic vascular resistance and by mean arterial pressure. In septic shock patients, APCO measurements assessed by FloTrac but also the established CCO measurements using the PAC did not meet the currently accepted statistical criteria indicating acceptable clinical performance.

Keywords: Cardiac output, measurement; Pulmonary artery catheter; Pulse wave analysis; Sepsis; Stroke volume, measurement; Thermodilution.

Publication types

  • Comparative Study
  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Calibration
  • Cardiac Output*
  • Catheterization, Peripheral / instrumentation
  • Catheterization, Peripheral / methods
  • Diagnosis, Computer-Assisted / instrumentation
  • Diagnosis, Computer-Assisted / methods*
  • Equipment Design
  • Equipment Failure Analysis
  • Female
  • Heart Function Tests / instrumentation
  • Heart Function Tests / methods
  • Humans
  • Male
  • Middle Aged
  • Pulmonary Wedge Pressure*
  • Pulse Wave Analysis / instrumentation*
  • Pulse Wave Analysis / methods
  • Reproducibility of Results
  • Saudi Arabia
  • Sensitivity and Specificity
  • Shock, Septic / diagnosis*
  • Software*
  • Switzerland
  • Thermodilution / methods