Autofluorescence of choroidal melanomas

Retin Cases Brief Rep. 2007 Summer;1(3):117-9. doi: 10.1097/ICB.0b013e31809ffbf0.

Abstract

Purpose: To report autofluorescence findings for two patients with choroidal melanomas.

Methods: Records and photographs for two patients with choroidal melanomas were reviewed. Fundus autofluorescence photography was performed using the Heidelberg confocal SLO system (Heidelberg Retina Angiograph; Heidelberg Engineering, Dossenheim, Germany).

Results: Both patients had lipofuscin over the melanoma. In Case 1, autofluorescence studies showed a linear streak of autofluorescence and patchy autofluorescence overlying the tumor. In Case 2, autofluorescence photographs showed the presence of small flecklike areas of autofluorescence over the melanoma.

Conclusion: Fundus autofluorescence photography is an alternative method for imaging lipofuscin over choroidal lesions.