J Vet Intern Med. 2014 Nov-Dec;28(6):1699-701. doi: 10.1111/jvim.12446. Epub 2014 Oct 1.

Relationship between serum symmetric dimethylarginine concentration and glomerular filtration rate in cats.

Author information

1
IDEXX Laboratories, Inc., Westbrook, ME.

Abstract

BACKGROUND:

Direct measurement of glomerular filtration rate (GFR) is the preferred method to assess renal function in cats, but it is not widely used in the diagnosis of chronic kidney disease (CKD). In cats with CKD, symmetric dimethylarginine (SDMA) has been shown to increase and to correlate with plasma creatinine concentrations.

HYPOTHESIS:

In cats, reduced GFR corresponds with increased serum SDMA concentration.

ANIMALS:

The study group consisted of ten client-owned cats whose GFR had been measured previously. Cats ranged in age from 11.1 to 16.9 years; both azotemic and nonazotemic animals were included.

METHODS:

Glomerular filtration rate was determined for each cat by plasma iohexol clearance using the three sample slope-intercept method, and serum SDMA concentration was measured by liquid chromatography-mass spectrometry.

RESULTS:

A linear relationship was observed between GFR and the reciprocal of serum SDMA concentration (R(2) = 0.82, P < .001). A similar relationship was found between GFR and the reciprocal of plasma creatinine concentration (R(2) = 0.81, P < .001).

CONCLUSIONS AND CLINICAL IMPORTANCE:

Increased serum SDMA concentrations were observed in cats with reduced renal function as determined by direct measurement of GFR. This finding indicates that SDMA could have clinical applications in the diagnosis of CKD in cats.

KEYWORDS:

Creatinine; Feline; Kidney; Renal

PMID:
25272985
PMCID:
PMC4895615
DOI:
10.1111/jvim.12446
[Indexed for MEDLINE]
Free PMC Article