Neurosurgery. 2015 Jan;76(1):25-31; discussion 31-2; quiz 32-3. doi: 10.1227/NEU.0000000000000556.

Validation of the supplemented Spetzler-Martin grading system for brain arteriovenous malformations in a multicenter cohort of 1009 surgical patients.

Author information

1
*Department of Anesthesia and Perioperative Care, ‡Department of Epidemiology and Biostatistics, §Center for Cerebrovascular Research, and ¶Department of Neurological Surgery, University of California, San Francisco, California; ‖Department of Neurological Surgery, Macquarie University, Sydney, Australia; #Department of Neurological Surgery, Massachusetts General Hospital, Boston, Massachusetts; **Division of Neurological Surgery, Barrow Neurological Institute, Phoenix, Arizona.

Abstract

BACKGROUND:

The supplementary grading system for brain arteriovenous malformations (AVMs) was introduced in 2010 as a tool for improving preoperative risk prediction and selecting surgical patients.

OBJECTIVE:

To demonstrate in this multicenter validation study that supplemented Spetzler-Martin (SM-Supp) grades have greater predictive accuracy than Spetzler-Martin (SM) grades alone.

METHODS:

Data collected from 1009 AVM patients who underwent AVM resection were used to compare the predictive powers of SM and SM-Supp grades. Patients included the original 300 University of California, San Francisco patients plus those treated thereafter (n = 117) and an additional 592 patients from 3 other centers.

RESULTS:

In the combined cohort, the SM-Supp system performed better than SM system alone: area under the receiver-operating characteristics curve (AUROC) = 0.75 (95% confidence interval, 0.71-0.78) for SM-Supp and AUROC = 0.69 (95% confidence interval, 0.65-0.73) for SM (P < .001). Stratified analysis fitting models within 3 different follow-up groupings (<6 months, 6 months-2 years, and >2 years) demonstrated that the SM-Supp system performed better than SM system for both medium (AUROC = 0.71 vs 0.62; P = .003) and long (AUROC = 0.69 vs 0.58; P = .001) follow-up. Patients with SM-Supp grades ≤6 had acceptably low surgical risks (0%-24%), with a significant increase in risk for grades >6 (39%-63%).

CONCLUSION:

This study validates the predictive accuracy of the SM-Supp system in a multicenter cohort. An SM-Supp grade of 6 is a cutoff or boundary for AVM operability. Supplemented grading is currently the best method of estimating neurological outcomes after AVM surgery, and we recommend it as a starting point in the evaluation of AVM operability.

PMID:
25251197
PMCID:
PMC4270816
DOI:
10.1227/NEU.0000000000000556
[Indexed for MEDLINE]