Format

Send to

Choose Destination
Biosens Bioelectron. 2014 Dec 15;62:189-95. doi: 10.1016/j.bios.2014.06.049. Epub 2014 Jun 27.

Copper nanoclusters as a highly sensitive and selective fluorescence sensor for ferric ions in serum and living cells by imaging.

Author information

1
The Key Laboratory of Luminescence and Real-Time Analysis, Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China.
2
Basic Department of Rongchang Campus, Southwest University, Chongqing 402460, China.
3
The Key Laboratory of Luminescence and Real-Time Analysis, Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China. Electronic address: zhenghz@swu.edu.cn.
4
The Key Laboratory of Luminescence and Real-Time Analysis, Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China. Electronic address: yuminghuang2000@yahoo.com.

Abstract

A simple, one-step facile route for preparation of water soluble and fluorescent Cu nanoclusters (NCs) stabilized by tannic acid (TA) is described. The as-prepared TA capped Cu NCs (TA-Cu NCs) are characterized by UV-vis spectroscopy, Fourier transform infrared (FT-IR) spectroscopy, luminescence, transmission electron microscopy (TEM), and X-ray photoelectron spectroscopy (XPS). The TA-Cu NCs show luminescence properties having excitation and emission maxima at 360 nm and 430 nm, respectively, with a quantum yield of about 14%. The TA-Cu NCs are very stable even in 0.3 M NaCl, and their luminescent properties show pH independent. The fluorescence (FL) of Cu NCs is strongly quenched by Fe(3+) through an electron transfer mechanism, but not by other metal ions. Furthermore, the FL of the TA-Cu NCs shows no changes with the addition of Fe(2+) or H2O2 individually. On this basis, a facile chemosensor was developed for rapid, reliable, sensitive, and selective sensing of Fe(3+) ions with detection limit as low as 10 nM and a dynamic range from 10 nM to 10 μM. The proposed sensor was successfully used for the determination of iron contents in serum samples. Importantly, the Cu NCs-based FL probe showed long-term stability, good biocompatibility and very low cytotoxicity. It was successfully used for imaging ferric ions in living cells, suggesting the potential application of Cu NCs fluorescent probe in clinical analysis and cell imaging.

KEYWORDS:

Cell imaging; Chemosensor; Cu nanoclusters; Ferric ions; Fluorescence probe

PMID:
24999996
DOI:
10.1016/j.bios.2014.06.049
[Indexed for MEDLINE]

Supplemental Content

Full text links

Icon for Elsevier Science
Loading ...
Support Center