Rev Sci Instrum. 2014 Jun;85(6):066108. doi: 10.1063/1.4884342.

Note: Design and initial results of a multi-pulsed intense electron beam source.

Author information

1
Institute of Fluid Physics, CAEP, Mianyang 621900, China.

Abstract

A multi-pulsed intense electron beam source is introduced, including the design and the initial experimental results. The source can generate a burst of three pulses of intense electron beams with energy of 2-3 MeV and beam intensities of around 2.5 kA. An inductive adder is chosen to generate the pulsed diode voltages and a dispenser cathode is chosen to emit electron beams. The test results indicate that the design of the source is reliable. The multi-pulsed diode voltage is up to 2.5 MV and the beam intensities are more than 2 kA at the exit of the source with small variation.

PMID:
24985872
DOI:
10.1063/1.4884342