Format

Send to

Choose Destination
See comment in PubMed Commons below
Acad Emerg Med. 2014 Feb;21(2):137-46. doi: 10.1111/acem.12315.

Feasibility and diagnostic accuracy of brief health literacy and numeracy screening instruments in an urban emergency department.

Author information

1
Division of Emergency Medicine, Barnes-Jewish Hospital, Washington University School of Medicine, St. Louis, MO.

Abstract

OBJECTIVES:

The objective was to evaluate the diagnostic accuracy of five health literacy screening instruments in emergency department (ED) patients: the Rapid Evaluation of Adult Literacy in Medicine-Revised (REALM-R), the Newest Vital Sign (NVS), Single Item Literacy Screens (SILS), health numeracy, and physician gestalt. A secondary objective was to evaluate the feasibility of these instruments as measured by administration time, time on task, and interruptions during test administration.

METHODS:

This was a prospective observational cross-sectional study of a convenience sampling of adult patients presenting during March 2011 and February 2012 to one urban university-affiliated ED. Subjects were consenting non-critically ill, English-speaking patients over the age of 18 years without aphasia, dementia, mental retardation, or inability to communicate. The diagnostic test characteristics of the REALM-R, NVS, SILS, health numeracy, and physician gestalt were quantitatively assessed by using the short Test of Functional Health Literacy in Adults (S-TOFHLA). A score of 22 or less was the criterion standard for limited health literacy (LHL).

RESULTS:

A total of 435 participants were enrolled, with a mean (±SD) age of 45 (±15.7) years, and 18% had less than a high school education. As defined by an S-TOFHLA score of 22 or less, the prevalence of LHL was 23.9%. In contrast, the NVS, REALM-R, and physician gestalt identified 64.8, 48.5, and 35% of participants as LHL, respectively. A normal NVS screen was the most useful test to exclude LHL, with a negative likelihood ratio of 0.04 (95% confidence interval [CI] = 0.01 to 0.17). When abnormal, none of the screening instruments, including physician gestalt, significantly increased the posttest probability of LHL. The NVS and REALM-R require 3 and 5 minutes less time to administer than the S-TOFHLA. Administration of the REALM-R is associated with fewer test interruptions.

CONCLUSIONS:

One-quarter of these ED patients had marginal or inadequate health literacy. Among the brief screening instruments evaluated, a normal NVS result accurately reduced the probability of LHL, although it will identify two-thirds of ED patients as high risk for LHL. None of the brief screening instruments significantly increases the probability of LHL when abnormal.

PMID:
24673669
PMCID:
PMC4042843
DOI:
10.1111/acem.12315
[Indexed for MEDLINE]
Free PMC Article
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Wiley Icon for PubMed Central
    Loading ...
    Support Center