Format

Send to

Choose Destination
See comment in PubMed Commons below

Direct parametric image reconstruction of rapid multi-tracer PET.

Author information

1
Department of Nuclear Medicine, Technische Universtität München, Germany.
2
Computer Aided Medical Procedures, Technische Universtität München, Germany.

Abstract

The separation of multiple PET tracers within an overlapped scan based on intrinsic difference of pharmacokinetics is challenging due to the limited SNR of PET measurements and high complexity of fitting models. This study developed a novel direct parametric reconstruction method by integrating a multi-tracer model with reduced number of fitting parameters into image reconstruction. To incorporate the multitracer model, we adopted EM surrogate functions for the optimization of the penalized log-likelihood. The algorithm was validated on realistic simulation phantoms and real rapid [18F]FDG and [18F]FLT PET imaging of mice with lymphoma mouse tumor. Both results have been compared with conventional methods and demonstrated evident improvements for the separation of multiple tracers.

PMID:
24505756
[Indexed for MEDLINE]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Loading ...
    Support Center