Format

Send to

Choose Destination
See comment in PubMed Commons below
Circ Arrhythm Electrophysiol. 2013 Oct;6(5):851-8. doi: 10.1161/CIRCEP.113.000318. Epub 2013 Aug 27.

Prevalence, characteristics, mapping, and catheter ablation of potential rotors in nonparoxysmal atrial fibrillation.

Author information

1
Faculty of Medicine & Institute of Clinical Medicine, National Yang-Ming University, Taipei, Taiwan.

Abstract

BACKGROUND:

Identification of critical atrial substrates in patients with nonparoxysmal atrial fibrillation (AF) failing to respond to pulmonary vein isolation is important. This study investigated the signal characteristics, substrate nature, and ablation results of rotors during AF.

METHODS AND RESULTS:

In total, 53 patients (age=55±8), 31 with persistent AF and 22 with long-lasting AF, underwent pulmonary vein isolation and substrate modification of complex fractionated atrial electrograms. Small-radius-reentrant rotors were identified from signal analyses of the dominant frequency and fractionation interval and nonlinear analyses (newly developed, beat-to-beat nonlinear measurement of the repetitiveness of the electrogram morphology>6 seconds). In 15% of the patients, activation maps demonstrated occurrences of rotor-like small-radius reentrant circuits (n=9; 1.1 per patient; cycle length=110±21 ms; diameter=11±6 mm) with fibrillation occurring outside these areas. Rotors were identified by conventional point-by-point mapping and signal analyses and were subsequently eradicated by catheter ablation in these patients. Persistent AF for <1 year, a smaller left atrial size, substrates with higher mean voltages and shorter total activation durations predicted a higher incidence of rotors (all P<0.05). In the multivariable model, areas of reentrant circuits exhibited a higher dominant frequency, kurtosis, and higher degree of a beat-to-beat electrogram similarity than areas without or outside the rotors (all P<0.05).

CONCLUSIONS:

Rotor-like re-entry with fibrillatory conduction was found in a limited number of patients with nonparoxysmal AF after pulmonary vein isolation. Those areas were characterized by rapid repetitive activity with a high degree of electrogram similarity.

KEYWORDS:

atrial fibrillation; atrium; catheter ablation; electrocardiography; mapping

PMID:
23983246
DOI:
10.1161/CIRCEP.113.000318
[Indexed for MEDLINE]
Free full text
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for HighWire
    Loading ...
    Support Center