Abstract

BACKGROUND:

FDA-approved HIV Antigen/Antibody combo (4th generation) immunoassays (IAs) can identify HIV-1 infections before the Western blot (WB) becomes positive. In the US, increased detection of acute HIV infections has been facilitated by using 4th generation IAs, but there is no FDA-approved 4th generation rapid test (RT). The Alere Determine™ HIV-1/2 Ag/Ab Combo (Determine Combo) RT detects and distinguishes HIV p24 Antigen (Ag) from Antibody (Ab) to HIV-1+HIV-2 and thus has the potential to improve diagnosis of acute HIV infection.

OBJECTIVE:

To evaluate the ability of Determine Combo RT to detect acute/early HIV-1 infections and HIV-2 antibody in well-characterized plasma specimens.

STUDY DESIGN:

In HIV-1 seroconverters from the US, Determine Combo reactivity was evaluated by performing the 50% cumulative frequency analysis and by comparing with 3rd and 4th generation IAs' reactivity. HIV-2 plasma specimens from Ivory Coast were tested with Determine Combo.

RESULTS:

The 50% cumulative frequency analysis in 17 seroconverters placed Determine Combo (Ag+/Ab-, Ag+Ab+, Ag-/Ab+) and Ab-component reactivity at 15.5 and 7 days before WB positivity, respectively. In 26 seroconverters, Determine Combo was reactive in 99.0% and 92.5% of 3rd and 4th generation IAs-reactive specimens, respectively. All HIV-2 plasma specimens were Ab-reactive/Ag-non-reactive by Determine Combo.

CONCLUSIONS:

Based on previous results with the same seroconversion panels, combined Ag/Ab reactivity of the Determine Combo appears between FDA-approved 4th and 3rd generation laboratory IAs. These data indicate that this RT could detect HIV-1 infection earlier than other RTs and it performs well in HIV-2 specimens.

KEYWORDS:

4th generation; Diagnostic; HIV-1/2; Rapid test

PMID:
23911678
DOI:
10.1016/j.jcv.2013.07.002
[Indexed for MEDLINE]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Elsevier Science
    Loading ...
    Support Center