Format

Send to

Choose Destination
J Arthroplasty. 2013 Oct;28(9 Suppl):191-4. doi: 10.1016/j.arth.2013.05.014. Epub 2013 Jun 21.

Tibial cementing in UKA: a three-dimensional analysis of the bone cement implant interface and the effect of bone lavage.

Author information

1
Department of Orthopaedics, Traumatology and Paraplegiology, Heidelberg University Hospital, Laboratory of Biomechanics and Implant Research, Schlierbacher Landstrasse 200a, Heidelberg, Germany.

Abstract

Loosening is a common cause for revision in cemented UKA. In a cadaver study, we analyzed the three-dimensional cement distribution under the tibial implant and the effect of bone lavage (pulsed lavage, syringe lavage) on maximum cement penetration and penetration volume. Analyses were determined by performing bone cuts in medio-lateral direction and converting this data into a 3D model. Pulsed lavage led to an increased mean maximum cement penetration 5.79 ± 2.63 mm and penetration volume 6471.34 ± 1156.43 mm(3) compared to syringe lavage 4.62 ± 2.61 mm, 5069.81 ± 1177.09 mm(3) (P<0.001; P<0.001). Our results show a complete cement mantle for both investigated lavage techniques. Cleansing the cancellous tibial bone bed using pulsed lavage is more effective than conventional syringe lavage and leads to a deeper cement penetration and lager cement penetration volume under the tibial component.

KEYWORDS:

cement interface; cement penetration; pulsed lavage; syringe lavage; unicompartmental knee arthroplasty

PMID:
23790498
DOI:
10.1016/j.arth.2013.05.014
[Indexed for MEDLINE]