Pediatr Radiol. 2013 Nov;43(11):1491-501. doi: 10.1007/s00247-013-2723-0. Epub 2013 Jun 5.

Clinically useful dilution factors for iodine and gadolinium contrast material: an animal model of pediatric digital subtraction angiography using state-of-the-art flat-panel detectors.

Author information

1
Department of Radiology, Division of Pediatric Interventional Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave., Cincinnati, OH, 45229-3030, USA, john.racadio@cchmc.org.

Abstract

BACKGROUND:

Iodinated and gadolinium contrast agents pose some risk for certain pediatric patients, including allergic-like reactions, contrast-induced nephropathy (CIN) and nephrogenic systemic fibrosis (NSF). Digital flat-panel detectors enhance image quality during angiography and might allow use of more dilute contrast material to decrease risk of complications that might be dose-dependent, such as CIN and NSF.

OBJECTIVE:

To assess the maximum dilution factors for iodine- and gadolinium-based contrast agents suitable for vascular imaging with fluoroscopy and digital subtraction angiography (DSA) on digital flat-panel detectors in an animal model.

MATERIALS AND METHODS:

We performed selective catheterization of the abdominal aorta, renal artery and common carotid artery on a rabbit. In each vessel we performed fluoroscopy and DSA during contrast material injection using iodinated and gadolinium contrast material at 100%, 80%, 50%, 33% and 20% dilutions. An image quality score (0 to 3) was assigned by each of eight evaluators. Intracorrelation coefficient, paired t-test, one-way repeated analysis of variance, Spearman correlation and receiver operating characteristic curve analysis were applied to the data.

RESULTS:

Overall the image quality scores correlated linearly with dilution levels. For iodinated contrast material, the optimum cut-off level for DSA when a score of at least 2 is acceptable is above 33%; it is above 50% when a score of 3 is necessary. For gadolinium contrast material, the optimum cut-off for DSA images is above 50% when a score of at least 2 is acceptable and above 80% when a score of 3 is necessary.

CONCLUSION:

Knowledge of the relationship between image quality and contrast material dilution might allow a decrease in overall contrast load while maintaining appropriate image quality when using digital flat-panel detectors.