Doses in sensitive organs during prostate treatment with a 60Co unit

Appl Radiat Isot. 2014 Jan:83 Pt C:227-9. doi: 10.1016/j.apradiso.2013.05.003. Epub 2013 May 9.

Abstract

Using thermoluminiscent dosimeters the absorbed dose in the bladder, rectum and thyroid have been evaluated when 200 cGy was applied to the prostate. The treatment was applied with a (60)Co unit. A water phantom was built and thermoluminiscent dosimeters were located in the position where the prostate, bladder, rectum and thyroid are located. The therapeutic beam was applied in 4 irradiations at 0, 90, 180 and 270° with the prostate at the isocenter. The TLDs readouts were used to evaluate the absorbed dose in each organ. The absorbed doses were used to estimate the effective doses and the probability of developing secondary malignacies in thyroid, rectum and bladder.

Keywords: Absorbed dose; Cobalt 60; Effective dose; Prostate cancer; TLD100; Water phantom.

MeSH terms

  • Cobalt Radioisotopes / therapeutic use*
  • Humans
  • Luminescence
  • Male
  • Prostatic Neoplasms / radiotherapy*
  • Radiotherapy Dosage

Substances

  • Cobalt Radioisotopes