Format

Send to

Choose Destination
See comment in PubMed Commons below
Anal Chem. 2013 May 21;85(10):5120-8. doi: 10.1021/ac400502v. Epub 2013 May 7.

Fluorescent Ru(phen)3(2+)-doped silica nanoparticles-based ICTS sensor for quantitative detection of enrofloxacin residues in chicken meat.

Author information

1
State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, P R China.

Abstract

A Ru(phen)3(2+)-doped silica fluorescent nanoparticle (FN)-based immunochromatographic test strip (ICTS) sensor was developed for rapid, high sensitivity, easy to use, and low cost quantitative detection of enrofloxacin (ENR) residues in chicken meat. The fluorescence signal intensity of the FNs at the test line (FI(T)) and control line (FI(C)) was determined with a prototype of a portable fluorescent strip reader. Unique properties of Ru(phen)3(2+) doped silica nanoparticles (e.g., large Stokes shift, high emission quantum yield, and long fluorescence lifetime) were combined with the advantages of ICTS and an easy to make portable fluorescent strip reader. The signal was based on FI(T)/FI(C) ratio to effectively eliminate strip to strip variation and matrix effects. Various parameters that influenced the strip were investigated and optimized. Quantitative ENR detection with the FNs ICTS sensor using 80 μL sample took only 20 min, which is faster than the commercial ELISA kit (that took 90 min). The linear range of detection in chicken extract was established at 0.025-3.500 ng/mL with a half maximal inhibitory concentration at 0.22 ± 0.02 ng/mL. Using the optimized parameters, the limit of detection (LOD) for ENR using the FNs ICTS sensor was recorded at 0.02 ng/mL in chicken extract. This corresponds to 0.12 μg/kg chicken meat which is two (2) orders of magnitude better that the maximum residue limits (MRLs) imposed in Japan (10 μg/kg) and three (3) orders of magnitude better than those imposed in China. The intra- and inter-assay coefficient of variations (CVs) were 6.04% and 12.96% at 0.5 ng/mL, 6.92% and 12.61% at 1.0 ng/mL, and 6.66% and 11.88% at 2.0 ng/mL in chicken extract, respectively. The recoveries using the new FNs ICTS sensor from fifty (50) ENR-spiked chicken samples showed a highly significant correlation (R(2) = 0.9693) with the commercial enzyme-linked immunosorbent assay (ELISA) kit. The new FNs ICTS sensor is a simple, rapid, sensitive, accurate, and inexpensive quantitative detection of ENR residues in chicken meat and extracts.

PMID:
23614687
DOI:
10.1021/ac400502v
[Indexed for MEDLINE]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for American Chemical Society
    Loading ...
    Support Center