J Cardiovasc Electrophysiol. 2013 Jun;24(6):723-7. doi: 10.1111/jce.12058. Epub 2012 Dec 21.

Our approach to minimize risk of epicardial access: standard techniques with the addition of electroanatomic mapping guidance.

Author information

1
Cardiac Arrhythmia Center, Ronald Reagan UCLA Medical Center, David Geffen School of Medicine, University of California-Los Angeles, CA 90095, USA.

Abstract

Epicardial mapping and ablation is increasingly being performed for the treatment of complex arrhythmias. Right ventricular (RV) puncture remains the most common complication, with damage to surrounding non-cardiac structures also a concern. We describe the standard techniques used in our lab essential for safe epicardial access, as well as a novel technique incorporating electroanatomic mapping (EAM) guidance. In a series of 8 patients referred for ventricular tachycardia ablation, an RV endocardial voltage map was created using EAM systems. EAM images were fused with preprocedure CT scans when available. A 17G Tuohy needle was integrated with the EAM system by attaching the needle to sterile electrode clamps. EAM location points were used in conjunction with standard access techniques until epicardial access was obtained. Epicardial access was successfully obtained in 8/8 (100%) patients. Successful access without RV puncture was achieved in 7/8 (88%) cases. This proof of concept study demonstrates that EAM systems can be used as an adjunct to standard access techniques to visualize and facilitate pericardial access.

PMID:
23279311
PMCID:
PMC3696725
DOI:
10.1111/jce.12058
[Indexed for MEDLINE]
Free PMC Article
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Wiley Icon for PubMed Central
    Loading ...
    Support Center