Format

Send to

Choose Destination
See comment in PubMed Commons below
Acta Orthop Belg. 2012 Oct;78(5):688-93.

Internal fixation of a traumatic fracture around a hip resurfacing arthroplasty using the proximal femoral locking compression plate.

Author information

1
Department of Trauma and Orthopaedics, James Cook University Hospital, Middlesbrough TS4 3TG, UK.

Abstract

We report on a 40-year-old man who sustained a traumatic extracapsular fracture of the proximal femur with a Birmingham Hip Resurfacing in situ. It was decided to retain the resurfacing implant and a proximal femoral periarticular locking compression plate (Synthes) was used to stabilise the fracture. The patient regained full range of pain-free movement, and was bearing his full weight on the operated leg by 18 weeks. He had a Harris Hip score of 90. Fractures around hip resurfacing arthroplasties are an emerging problem, and a literature review reveals two distinct modes of presentation i.e. 'atraumatic' and 'traumatic' fractures. We elaborate on these two different fracture patterns, with emphasis on the epidemiology, biomechanical considerations, and management strategies for the 'traumatic' type of periprosthetic fracture.

PMID:
23162970
[Indexed for MEDLINE]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Loading ...
    Support Center