Format

Send to

Choose Destination
See comment in PubMed Commons below
Rev Sci Instrum. 2012 Sep;83(9):093501. doi: 10.1063/1.4748859.

The resistive bolometer for radiated power measurement on EAST.

Author information

1
Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Hefei 230031, China.

Abstract

The resistive bolometer system has been successfully employed on experimental advanced superconducting tokamak for the first time to measure the radiated power of plasma. The bolometer detectors are based on 4 μm thick Pt absorbers deposited on 1.5 μm thick SiN membranes. The system consists of 3 cameras with a total of 48 channels. The detector and the system setup are described in detail. The detector calibration and typical measurement results are presented as well.

PMID:
23025621
DOI:
10.1063/1.4748859