Multiple interstrut cavities: a potential mechanism for very late stent thrombosis? Insights from optical coherence tomography

JACC Cardiovasc Interv. 2012 Sep;5(9):995-6. doi: 10.1016/j.jcin.2012.03.026.
No abstract available

Publication types

  • Case Reports

MeSH terms

  • Angina, Unstable / therapy*
  • Cardiovascular Agents / administration & dosage
  • Coronary Angiography
  • Coronary Thrombosis / diagnostic imaging
  • Coronary Thrombosis / etiology
  • Coronary Thrombosis / pathology*
  • Coronary Thrombosis / therapy
  • Coronary Vessels / pathology*
  • Drug-Eluting Stents*
  • Humans
  • Hyperplasia
  • Male
  • Middle Aged
  • Neointima
  • Percutaneous Coronary Intervention / adverse effects
  • Percutaneous Coronary Intervention / instrumentation*
  • Predictive Value of Tests
  • Prosthesis Design
  • Sirolimus / administration & dosage
  • Thrombectomy
  • Time Factors
  • Tomography, Optical Coherence*
  • Treatment Outcome

Substances

  • Cardiovascular Agents
  • Sirolimus